Windows Integrity Management Agents Reference
Event DescriptionEvent SeverityEvent ID
The configured CPU generation is not supported Probable Cause: The configuration
contains an unsupported CPU generation Recommended Action: Modify the
configuration to use a supported CPU generation SNMP Trap:
hpevtCPUConfigNotSupprt - 11703 in HPIFPTRAP.MIB.Error11703
An ISA UART was created without a data structure. A PCI UART structure exists
Probable Cause: The ISA UART code was called when a PCI UART structure and no
ISA UART structure were created. Recommended Action: Verify that the configuration
contains the correct UART type. SNMP Trap: hpevtISAUARTcreatWithoutDatStrct
- 11705 in HPIFPTRAP.MIB.Error11705
A TCGETS or TCSETS IOCTL failed. The errno status will be in a subsequent event.
Probable Cause: The device is not configured or is not the proper type. Recommended
Action: Check the configuration SNMP Trap: hpevtTCGETorIOCTLFail - 11706 in
HPIFPTRAP.MIB.Error11706
A stat call on the PMAN failed. The next event contains the failure errno. Probable
Cause: The device does not exist or is not available Recommended Action: Check the
configuration and verify the device SNMP Trap: hpevtStatCallPMANFail - 11707 in
HPIFPTRAP.MIB.Error11707
The virtual machine driver could not be opened Probable Cause: The virtual machine
software is not properly installed or is not running Recommended Action: Restart
the virtual machine. If this fails verify that it is properly installed. SNMP Trap:
hpevtVMDrvNotOpen - 11708 in HPIFPTRAP.MIB.Error11708
The virtual machine driver could not create a virtual machine Probable Cause: The
PMAN kernel has insufficient memory available to create a guest Recommended
Action: Add memory or reduce memory use SNMP Trap: hpevtVMDrvNotCreatVM
- 11709 in HPIFPTRAP.MIB.Error11709
Could not create a file system node for communication between the vmm driver and
the virtual machine. The next event contains the error from the Unix system call.
Probable Cause: Insufficient resources or file system problem Recommended Action:
Verify that the root file system has no errors and is not full. SNMP Trap:
hpevtNotAbleCreatNodeForComm - 11710 in HPIFPTRAP.MIB.Error11710
The vm device was created but cannot be opened Probable Cause: File system error
or PMAN has insufficient resources Recommended Action: Verify that the root file
system has no errors and that the PMAN has sufficient memory. SNMP Trap:
hpevtVMNotOpen - 11711 in HPIFPTRAP.MIB.Error11711
The virtual machine driver has not been loaded Probable Cause: HPVM has not been
started Recommended Action: Start HPVM SNMP Trap: hpevtVMDrvNotLoad -
11712 in HPIFPTRAP.MIB.Error11712
An attempt to create a thread on the PMAN has failed. The next event contains the
Unix error number. Probable Cause: Insufficient resources Recommended Action:
Reduce guest resources or add memory SNMP Trap: hpevtCreatThreadPMANFail
- 11718 in HPIFPTRAP.MIB.Error11718
VM Driver was unable to communicate with virtual machine Probable Cause: This
is an internal error. Recommended Action: If this continues to occur, reinstall the
software. If this does not fix the problem contact your HP support representative.
SNMP Trap: hpevtVMDrvUnableCommVM - 11719 in HPIFPTRAP.MIB.Error11719
The configuration file could not be read Probable Cause: The configuration file is
missing or damaged. Recommended Action: Restore the configuration from a backup
or recreate the guest. SNMP Trap: hpevtConfigUnableToRd - 11720 in
HPIFPTRAP.MIB.Error11720
Memory allocation for a firmware table has failed. The data contains the name of the
firmware table. Probable Cause: Insufficient memory available Recommended Action:
Increase available memory or swap file space SNMP Trap: hpevtMemAllocFWTblFail
- 11721 in HPIFPTRAP.MIB.Error11721
Platform Agent Events 91