User Service Guide, Third Edition - HP Integrity rx4640 Server
Table Of Contents
- HP Integrity rx4640 Server User Service Guide
- Table of Contents
- About This Document
- 1 Introduction
- 2 Controls, Ports, and LEDs
- 3 Powering Off and Powering On the Server
- 4 Removing and Replacing Components
- Safety Information
- Service Tools Required
- Accessing a Rack Mounted Server
- Accessing a Pedestal Mounted Server
- Removing and Replacing the Front Bezel
- Removing and Replacing the Front and Top Covers
- Removing and Replacing the Memory Extender Board
- Removing and Replacing Memory DIMMs
- Removing and Replacing the Processor Extender Board
- Removing and Replacing a Processor
- Removing and Replacing Hot-Swappable Chassis Fans
- Removing and Replacing the I/O Baseboard
- Removing and Replacing Hot-Pluggable PCI-X Cards
- Removing and Replacing OLX Dividers
- Removing and Replacing Core I/O Cards
- Removing and Replacing the Server Battery
- Removing and Replacing Hard Disk Drives
- Removing and Replacing the SCSI Backplane Board
- Removing and Replacing the Midplane Riser Board
- Removing and Replacing the Power Supplies
- Removing and Replacing the Power Distribution Board
- Removing and Replacing the DVD Drive
- Removing and Replacing the DVD I/O Board
- Removing and Replacing the Display Board
- Removing and Replacing the QuickFind Diagnostic Board
- 5 Troubleshooting
- Troubleshooting Tips
- Possible Problems
- Troubleshooting Using LED Indicators
- Diagnostics
- Recommended Cleaning Procedures
- Where to Get Help
- A Parts Information
- B Booting the Operating System
- Operating Systems Supported on HP Integrity Servers
- Configuring System Boot Options
- Booting and Shutting Down HP-UX
- Booting and Shutting Down HP OpenVMS
- Booting and Shutting Down Microsoft Windows
- Booting and Shutting Down Linux
- C Utilities
- Extensible Firmware Interface Boot Manager
- EFI/POSSE Commands
- Specifying SCSI Parameters
- Using the Boot Configuration Menu
- Index

Table C-1 EFI Commands (continued)
DefinitionBCH Command Parameters (PA-RISC)BCH Command
Equivalent (PA-RISC)
EFI Shell Command
Display boot-related
information
Boot infoEFI boot manager
Seconds allowed for boot
attempt
[0-200]BootTimerautoboot
Config/deconfig processor[<cpu>][ON|OFF]]CPUconfigcpuconfig
Display or set boot tests
execution
[ON|OFF] or [test] [RUN|SKIP]FastBootboottest
Read or set the date[cn:yr:mo:dy:hr:mn[:ss]]Timedate
Read or set the real time
clock
[cn:yr:mo:dy:hr:mn[:ss]]Timetime
INformation
Display all server
information
ALLinfo all
Display boot-releated
information
BootINfoinfo boot
Display cache informationCAcheinfo cpu
Display revision number of
major VLSI
ChipRevisionsinfo chiprev
Display FRU informationFRUMP command <df>
Display firmware version for
PDC, ICM, and complex
FwrVersioninfo fw
Display firmware version for
PDC, ICM, and complex
IOinfo io
Display core LAN station
address
LanAddresslanaddress
Display memory informationMemoryinfo mem
Display processor
information
PRocessorinfo cpu
SERvice
Clear (zero) the contents of
PIM
CLEARPIMerrdump clear
Read memory locations
scope of page deallocation
<addr> [<len>] [<type>]MemReadmm
Display or clear the page
deallocation table
page deallocation
table (pdt)
pdt
Display PIM information[<proc>] [HPMC|LPMC|TOC|ASIC]]processor internal
memory (PIM)
errdump mca
errdump cmc
errdump init
EFI/POSSE Commands
This section describes the EFI/POSSE commands developed for the server.
EFI/POSSE Commands 135