User Service Guide, Third Edition - HP Integrity rx4640 Server
Table Of Contents
- HP Integrity rx4640 Server User Service Guide
- Table of Contents
- About This Document
- 1 Introduction
- 2 Controls, Ports, and LEDs
- 3 Powering Off and Powering On the Server
- 4 Removing and Replacing Components
- Safety Information
- Service Tools Required
- Accessing a Rack Mounted Server
- Accessing a Pedestal Mounted Server
- Removing and Replacing the Front Bezel
- Removing and Replacing the Front and Top Covers
- Removing and Replacing the Memory Extender Board
- Removing and Replacing Memory DIMMs
- Removing and Replacing the Processor Extender Board
- Removing and Replacing a Processor
- Removing and Replacing Hot-Swappable Chassis Fans
- Removing and Replacing the I/O Baseboard
- Removing and Replacing Hot-Pluggable PCI-X Cards
- Removing and Replacing OLX Dividers
- Removing and Replacing Core I/O Cards
- Removing and Replacing the Server Battery
- Removing and Replacing Hard Disk Drives
- Removing and Replacing the SCSI Backplane Board
- Removing and Replacing the Midplane Riser Board
- Removing and Replacing the Power Supplies
- Removing and Replacing the Power Distribution Board
- Removing and Replacing the DVD Drive
- Removing and Replacing the DVD I/O Board
- Removing and Replacing the Display Board
- Removing and Replacing the QuickFind Diagnostic Board
- 5 Troubleshooting
- Troubleshooting Tips
- Possible Problems
- Troubleshooting Using LED Indicators
- Diagnostics
- Recommended Cleaning Procedures
- Where to Get Help
- A Parts Information
- B Booting the Operating System
- Operating Systems Supported on HP Integrity Servers
- Configuring System Boot Options
- Booting and Shutting Down HP-UX
- Booting and Shutting Down HP OpenVMS
- Booting and Shutting Down Microsoft Windows
- Booting and Shutting Down Linux
- C Utilities
- Extensible Firmware Interface Boot Manager
- EFI/POSSE Commands
- Specifying SCSI Parameters
- Using the Boot Configuration Menu
- Index
Memory
• 16 DIMM slots on standard memory extender board
• 32 DIMM slots on optional memory extender board
• Minimum memory size of 1 GB (four 256 MB DIMMs)
• Maximum memory size of 128 GB (4 GB DIMMs on 32-slot memory extender board)
• 256 MB, 512 MB, 1 GB, 2 GB, and 4 GB standard 184 pins 2.5V DDR 200, CL2, registered,
ECC
• 200 MHz memory bus frequency, 400 MTransfers/s data, 12.8 GB/s peak data bandwidth
• DIMMs loaded by quads enable interleaved mode and chip spare
PCI Riser
• Two dedicated PCI slots (LAN and SCSI)
• Four hot-pluggable PCI-X 66 MHz, 64-bit, 3.3V, 25W slots with shared busses and I/O. Slots
3 and 4 share a PCI-X bus and slots 5 and 6 share a PCI-X bus
• Two hot-pluggable PCI-X 133 MHz 64-bit 3.3V 25W slots
Internal Core I/O
• Dual channel SCSI U320 interface, two internal 68-pin connectors, two 68-pin external
connectors
• The SCSI backplane is configured as either one or two channels
• One internal IDE connector for a slim-line optical device (CD and DVD)
• No floppy connector
External Core I/O
• Three external DB-9 ports (MP local, auxiliary, remote)
• Two external USB 2.0 ports
• Two SCSI Ultra320 68-pin connectors
• Two 10/100/1000Base-T ethernet LAN port
• One 10/100 integrated Lights Out Management Processor (iLO MP) LAN port
• One VGA port
Power Supply Unit
• 1200 W output power
• Redundant and hot-swappable power supplies
Motherboard Manageability
• Baseboard Management Controller (BMC)
• Temperature monitoring and fans regulation by BMC
• Includes diagnostic panel LED display that shows server health
• Hardware diagnostics by BMC displayed by diagnostic panel LED
• IPMI protocol for communication between BMC/server/MP card
• Locator front/rear LEDs
• Field replacement units monitoring by BMC
Enhanced Server Manageability Using the iLO MP
• LAN, telnet, and SSH console
• Web GUI
• Serial port for local console