Slots 10, 11, and 12 are the highest performance slots in the system. Each of these slots provide an individual
bus with a 500 MB/second peak data rate at 133 MHz.
Installing a PCI Card
The server may contain up to 12 PCI cards. PCI cards are located in the side service bay.
WARNING Voltages are present at various locations within the server whenever an AC power
source is connected. This voltage is present even when the main power switch is in
the off position.
Ensure that the system is powered-down and all power sources have been
disconnected from the server prior to installing a PCI card.
Failure to observe this warning could result in personal injury or damage to
equipment.
CAUTION Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD
safety precautions could result in damage to the server.
To install a PCI card, perform the following steps:
1. Remove the appropriate PCI slot cover from the rear of the chassis.