Windows Integrity Enterprise Edition and Datacenter Edition Release Notes

Workaround Uninstall HP StorageWorks FC-HBA Configuration Utilities by QLogic for
Windows Server 2003 Itanium Based Systems revision 2.0.30.78 before installing
revision 5.0.0.4.
Emulex HBAs use different driver
Issue After performing an OS installation using Microsoft reinstall media or updating
an existing installation using the Support Pack from the HP Smart Setup CD,
the Emulex HBAs now use the STORPORT driver instead of the SCSIPort driver
previously used.
Servers All Integrity
Workaround This is not an error. HP is making the STORPORT driver the new default for
Emulex 4G PCI-X 2.0 and PCI-Express HBAs because this driver offers improved
performance and manageability features. However, if you are currently running
the SCSIPort driver and want to continue using, you must:
1. Uninstall the STORPORT driver after using the Microsoft reinstall media
or clear the Emulex Storport driver checkbox during the Support
Pack update from the HP Smart Setup CD.
2. Install the SCSIPort driver using the Smart Component in the “Others”
directory on the HP Smart Setup CD. This driver is also available for
download at http://www.hp.com/.
MSA fails with Storport driver installed
Issue MSA flash utility version 6.86.1.52 used on Active-Active MSA Controllers, and
version 5.10.1.52 used on Active-Passive Controllers will fail to run when the
latest Storport driver (KB916048) is installed.
Servers All Integrity
Workaround Use the MSA Flash utility with the fix that will be available on the HP web site
at the following Web site:
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us&
prodNameId=415600&prodTypeId=12169&prodSeriesId=415598&swLang=13&swEnvOID=1060
LUNs undetected by ACU
Issue The ACU will not detect any LUNs attached to an AB379A or AB429A HBA
that has been swapped or added using the Online Add/Replace function while
the ACU was running.
Servers sx2000, rx8640, rx7640, rx6600, rx3600
Workaround Stopping and restarting the ACU corrects this issue. The ACU will then see the
LUNs attached to the AB 379A or AB 429A HBAs.
HBA removal fails
Issue When attempting to remove the AB379A or AB429A HBA using the Online
Replace functionality, a message appears:
The device Qlogic Fibre Channel Adapter cannot be
stopped because a program is still accessing it.
Servers sx2000, rx8640, rx7640, rx6600, rx3600
Workaround Stop the Qlogic Management Suite Java Agent in the Services window
under Computer Management.
1.
2. Stop the AB379A or AB429A using the Safely Remove Hardware function.