Windows Integrity Enterprise Edition and Datacenter Edition Release Notes

System Management Homepage (SMH)
Components flagged with red exclamation mark
Issue
When running the setup.exe command without having System Management
Homepage (SMH) installed on the system, some configurable components may
show up with a red exclamation mark (!) when viewed in the All Configurable
Components” category of the HP Remote Deployment Utility main window.
A pop-up window with the following message may also be displayed:
“One or more components that have been selected for installation require
configuration but are not configured. For the best results, it is recommended
that you configure the components before installation”.
Servers All Integrity
Workaround To make the red exclamation mark go away, copy the System Management
Homepage component to a writable location and then configure it.
Page lacks temperature sensor descriptions
Issue On rx2620 servers with firmware bundle version 8.1 or later, and on rx3600 and
rx6600 servers with firmware bundle version 13.2 or later, the System
Management Homepa ge > Recovery > Environment page shows temperature
sensors that are lacking a description under the Location column. These are a
new type of sensor that the management agent cannot read completely.
However, temperature event logging and alert generation are not affected by
this display issue.
Servers rx6600, rx3600, rx2660, rx2620
Workaround There is no workaround at this time.
Some components not shown
Issue The 5.1 version of Management Agents does not show the following components
under Version Control:
HP Storage Works Event Notification Driver for Ultra320 SCSI devices for
Windows Server 2003 on Itanium-based systems (CP006112, printss.sys)
HP Ultra 160 SCSI Controller Driver for Windows Server 2003 on Itanium
based systems (CP006358, sym_u3.sys)
HP Array Diagnostic Utility for Windows Server 2003 on Itanium-based
systems (CP006361, Hpadu.exe)
HP StorageWorks FC-HBA Configuration Utilities by Emulex for Windows
Server 2003 Itanium Based Systems (CP006084, HBAnyware.exe)
HP StorageWorks FC-HBA Configuration Utilities by QLogic for Windows
Server 2003 Itanium Based Systems (CP005831, SANSurferVer.exe)
Servers All Integrity
Workaround Access the component versions manually from the Support Pack, HP Smart
Setup CD, or by similar methods.
Another solution is to use https://127.0.0.1:2381 instead of https://localhost:2381.
SMH fails to open
Issue If Internet Explorer is configured to browse through a proxy server and the
Bypass proxy server for local addresses checkbox is not selected, attempting
to connect to the local SMH (https://localhost:2381) fails with a Page cannot
be displayed error.
Servers All Integrity
32 Release 5.1 Overview