12BSmart Array 158
Table 13-2 Class: HPSA_ArraySystem (CIM_ComputerSystem)
Property name Property implementation
CIM_ManagedElement
ElementName Controller/Storage System name and location
Examples:
• Smart Array in Slot 3, for internal
• MSA500 in SystemCab03, for external
CIM_ManagedSystemElement
OperationalStatus[0] Overall status of the Array System and attached
devices. This is calculated per the algorithm desciribed
in the HP Smart Array Profile.
• 0 (Unknown)
• 2 (OK)
• 3 (Degraded)
• 6 (Error)
StatusDescriptions[0] More info for OperationalStatus result. This provides a
short decription to identify who is contributing to non-
OK status.
Examples:
• Logical Drive Failure
• Physical Drive Degraded/Failed
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_System
CreationClassName HPSA_ArraySystem
Name Controller Serial Number
NameFormat Other
CIM_ComputerSystem
• Dedicated[0]: 3 (Storage)
Dedicated
• Dedicated[1]: 15 (Block Server)
IdentifyingDescriptions Other Vendor Specific Name
OtherIdentifyingInfo Controller Serial Number
Identify() See HP Smart Array Profile