HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 205
Table 13-90 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
Table 13-91 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description Logical Drive status has now changed to OK
AlertingMangedElement WBEM path of the HPSA_StorageVolume Class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1201
ProviderName SmartArray
RecommendedActions No action required
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical Drive Status is now OK
EventCategory 6 (Primary Storage)
ProbableCause 0