HP Insight Management WBEM Providers on Integrity Servers Data Sheet
12BSmart Array 207
Table 13-91 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationalStatus values for Storage Volume
• DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
• DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Table 13-92 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Logical Drive Status has changed to ERROR status.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1202
ProviderName SmartArray
RecommendedActions Check for physical drive failed or removed.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical Drive Status is now ERROR
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)