HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 211
Table 13-93 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name Property implementation
HWLogicalLocation Logical drive number & RAID Level.
For example, LogicalDrive 1 (RAID 1+0).
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationStatus values for Storage Volume
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Table 13-94 HPSA_DeviceIndication: Controller status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Status has changed to a status of OK.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1001
ProviderName SmartArray
RecommendedActions No action needed
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller status change OK