HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 229
Table 13-102 HPSA_DeviceIndication: Controller Cache status changed to OK
Property name Property implementation
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
Table 13-103 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Temporarily Disabled. This may be caused by a rebuild
or configuration change, normal operation will return
after background operations have completed.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1062
ProviderName SmartArray
RecommendedActions No Action required
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is set to Temporarily
Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication