HP Insight Management WBEM Providers on Integrity Servers Data Sheet
12BSmart Array 231
Table 13-103 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
Table 13-104 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Permanently Disabled. Controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1063
ProviderName SmartArray
RecommendedActions Check Cache controller error code. Run diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is Permanently Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication