HP Insight Management WBEM Providers on Integrity Servers Data Sheet

12BSmart Array 240
Table 13-108 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name Property implementation
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
Table 13-109 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Temperature sensor Status changed to Warning
Condition. This indicates the enclosure temperature is
above normal, otherwise enclosure is still operating
normally.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1562
ProviderName SmartArray
RecommendedActions Verify fan and power supply operation for enclosure.
Verify ambient room temperature is within guidelines.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor Status changed to Warning
Condition.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication
For Windows 2003 64-bit: 70
OSType
For Windows 2008 64-bit: 77