HP Insight Management WBEM Providers on Integrity Servers Data Sheet
14BSAS HBA 319
Table 15-77 HPSAS_DeviceIndication: Logical Drive status OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 15-78 HPSAS_DeviceIndication: Logical Drive status ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Error.
AlertingMangedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical drive status Error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Logical Drive Status Changed to Error
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>