HP Insight Management WBEM Providers on Integrity Servers Data Sheet
14BSAS HBA 324
Table 15-80 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
Table 15-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply has changed to
Fully Redundant.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 302
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Redundant power supply status OK
EventCategory 17 (Primary Storage Power)
ProbableCause 1 (Other)
ProbableCauseDescription Redundant Power Supply Status Changed to OK
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77