HP Insight Management WBEM Providers on Integrity Servers Data Sheet
14BSAS HBA 326
Table 15-82 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power supply status Redundant Degraded
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power supply failure)
ProbableCauseDescription Redundant Power Supply Degraded
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication