HP Insight Management WBEM Providers on Integrity Servers Data Sheet

14BSAS HBA 329
Table 15-83 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name Property implementation
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have
N/A or “” values.
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
Table 15-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.