HP Insight Management WBEM Providers on Integrity Servers Data Sheet
15BSCSI HBA 369
Table 16-62 HPSCSI_DeviceIndication: Physical Drive status set to OK
Property name Property implementation
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
Table 16-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity Severity (for example, 5 (Major))
IndicationTime Time of indication
CIM_AlertIndication
Description SCSI physical disk has a status of ERROR and can no
longer return data
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
ProviderName SCSIHBA
RecommendedActions Replace the disk drive.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical disk ERROR.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Error
ProviderVersion 2.2.0.0
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>