HP Insight Management WBEM Providers on Integrity Servers Data Sheet

15BSCSI HBA 389
Table 16-74 HPSCSI_DeviceIndication: Power Supply status OK
Property name Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
Table 16-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description One of the component power supplies that make up
the redundant power supply has failed. The drive
system (either a drive subsystem or a power supply for
the main unit) continues to operate. However, if the
remaining power supply should fail, the drive system
will lose all power and data loss could occur
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 20
ProviderName SCSIHBA
RecommendedActions Schedule replacement of redundant power supply