HP Insight Management WBEM Providers on Integrity Servers Data Sheet
15BSCSI HBA 390
Table 16-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name Property implementation
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage enclosure redundant power supply
degraded.
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Degraded
ProviderVersion 2.2.0.0
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment