HP Insight Management WBEM Providers on Integrity Servers Data Sheet
15BSCSI HBA 400
Table 16-81 HPSCSI_DeviceIndication: Fan status change - ERROR
Property name Property implementation
CIM_AlertIndication
Description A fan has failed and there are not enough fans in the
fan subsystem to keep the enclosure cool.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 16
ProviderName SCSIHBA
RecommendedActions Check your fan subsystem as soon as possible.
Continued operation can cause failure of the drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage enclosure fan is failed
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan Failure)
ProbableCauseDescription Fan Failure
ProviderVersion 2.2.0.0
NetworkAddresses A list of all the IP addresses of the computer system
generating the indication
• For Windows 2003 64-bit: 70
OSType
• For Windows 2008 64-bit: 77
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication