HP Insight Management WBEM Providers on Integrity Servers Data Sheet

3BSystem Power Supply 48
4-3-8 HP_SystemPowerSupply
HP_SystemPowerSupply is used to represent an association between HP_PowerSupply and the
computer system that contains this power supply. The Windows implementation class is
HP_WinSystemPowerSupply.
Table 4-9 Class: HP_SystemPowerSupply
Property name Property implementation
GroupComponent References HP_ComputerSystem
PartComponent References HP_PowerSupply
4-3-9 HP_Location
HP_Location is used to model power supply locations on Integrity servers. The Windows
implementation class is HP_WinPowerSupplyLocation.
Table 4-10 Class: HP_Location
Property name Property implementation
CIM_ManagedElement
Caption Power Supply n, where n represents the power supply
position printed on the system labeling.
Description The location of the power supply n. Refer to power
supply position n printed on the system.
ElementName Power Supply n, where n represents the power supply
position printed on the system labeling.
CIM_Location
Name Unique identifier for this power supply location
instance
PhysicalPosition n, where n represents the power supply position
printed on the system.
HP_Location
ElementLocationTag Power Supply n, where n represents the power supply
position printed on the system.
ElementLocationTagDesc 0 (HoodTag)
4-3-10 HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows implementation class is HP_WinPowerSupplyElementLocation.