HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Unexpected trap. Probable Cause: An unexpected trap has occurred. During System
Firmware boot time this indicates the system has requested a trap that firmware has
not registered. During OS run time it indicates the system has requested a trap that
is not recognized in the OS's trap table. Recommended Action: If at FW boot time,
reboot or upgrade System FW. If problem persists contact your HP representative
for support. If at OS run time, verify that the OS has properly installed its trap handler,
and that only valid traps are caused. Investigate what could cause the trap that is
signaled by the event or why the OS has not properly installed the trap handler. If
problem persists contact your HP representative for support. WBEM EventID: 263.
WBEM ProviderName: FPL_IndicationProviderError5107
CPU unknown boot error. Probable Cause: Unknown error. Recommended Action:
Reboot or update System FW. If problem persists contact your HP representative for
support. WBEM EventID: 264. WBEM ProviderName: FPL_IndicationProviderError5108
CC errors PAL failure. Probable Cause: SFW has detected a PAL Failure.
Recommended Action: Reboot, update SFW if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 265. WBEM ProviderName:
FPL_IndicationProviderWarning5118
Expected MC vector unregistered. Probable Cause: Expected Machine Check Vector
not registered at the time of an Expected Machine Check Recommended Action:
Contact HP support to troubleshoot the problem. WBEM EventID: 266. WBEM
ProviderName: FPL_IndicationProviderWarning5119
INIT initiated. Probable Cause: Software has requested an INIT or the INIT button
has been pressed. Recommended Action: No action is required. WBEM EventID: 267.
WBEM ProviderName: FPL_IndicationProviderError5121
Expected I/O host bridge is missing. Probable Cause: I/O host bridge failure. An
incorrect I/O backplane is installed. Recommended Action: Contact your HP
representative to check the I/O host bridge and the I/O backplane. WBEM EventID:
268. WBEM ProviderName: FPL_IndicationProviderWarning5123
LBA has unexpected number of I/O slots. Probable Cause: The firmware needs to be
updated. An incorrect I/O backplane is installed. Recommended Action: Contact
your HP representative to check the firmware and the I/O backplane. WBEM EventID:
269. WBEM ProviderName: FPL_IndicationProviderWarning5124
I/O rope width does not match expected value. Probable Cause: The firmware needs
to be updated. An incorrect I/O backplane is installed. Recommended Action: Update
SFW. If problem persists, contact your HP representative to check the I/O backplane.
WBEM EventID: 270. WBEM ProviderName: FPL_IndicationProviderWarning5125
Found unexpected I/O host bridge. Probable Cause: The firmware needs to be
updated. An incorrect I/O backplane is installed. Recommended Action: Update
SFW. If problem persists, contact your HP representative to check the I/O backplane.
WBEM EventID: 271. WBEM ProviderName: FPL_IndicationProviderWarning5127
PCI clock DLL error. Probable Cause: Failed I/O chipset. Failed I/O backplane.
Recommended Action: Contact your HP representative to check the I/O chipset and
backplane. WBEM EventID: 272. WBEM ProviderName: FPL_IndicationProviderWarning5130
PCI hot plug controller failed. Probable Cause: Hot-plug controller failure. I/O host
bridge failure. Recommended Action: Contact your HP representative to check the
hot-plug controller and the I/O host bridge. WBEM EventID: 273. WBEM
ProviderName: FPL_IndicationProviderWarning5131
Found unknown I/O rope width. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. WBEM
EventID: 274. WBEM ProviderName: FPL_IndicationProviderWarning5132
I/O LBA clear error failed. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. WBEM EventID:
275. WBEM ProviderName: FPL_IndicationProviderWarning5133
Platform Events 17