Error in temporary mdt area. Probable Cause: The memory area where the MDT is
supposed to be built has an error in it, so the MDT cannot be built there.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProviderError5155
Failed to find lmmio entry in mdt. Probable Cause: The MDT table is bad because it
did not have an LMMIO entry in it. Recommended Action: Reboot, if problem persists
contact your HP representative for support. WBEM EventID: 294. WBEM
ProviderName: FPL_IndicationProviderError5156
Memory page zero bad. Probable Cause: Memory page 0 was slated for deallocation
in the PDT. Recommended Action: FW is written such that this event should never
be generated. If the user sees this event, please contact HP support. WBEM EventID:
295. WBEM ProviderName: FPL_IndicationProviderError5157
Failed to find space in mdt. Probable Cause: FW requested an entry in the MDT, and
there wasn't a large enough chunk of contiguous memory for the requested size.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 296. WBEM ProviderName: FPL_IndicationProviderError5158
Media failure: info was not retrieved/logged. Probable Cause: The Error handler has
failed to retrieve or log data due to a media failure. Recommended Action: Reboot
if necessary, if problem persists contact your HP representative for support. WBEM
EventID: 297. WBEM ProviderName: FPL_IndicationProviderWarning5159
Bus interface register test failed. Probable Cause: The CEC failed the register test.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 298. WBEM ProviderName: FPL_IndicationProviderWarning5160
Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps
to cache line 0 is in a chipspare condition Recommended Action: Contact HP support
WBEM EventID: 299. WBEM ProviderName: FPL_IndicationProviderWarning5161
DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM
is not loaded in order to allow for proper operation of the DIMM specified in the
physical location. Recommended Action: Refer to the user's manual for Memory
loading instructions. WBEM EventID: 300. WBEM ProviderName:
FPL_IndicationProviderWarning5171
DIMM SPD checksum failed. Probable Cause: The DIMMs SPD EEPROM got
corrupted. Recommended Action: Contact HP Support personnel to troubleshoot
the problem WBEM EventID: 301. WBEM ProviderName: FPL_IndicationProviderWarning5172
DIMM SPD fatal error. Probable Cause: Detection of SPD error type - various types
Recommended Action: Reseat or replace the DIMM. If problem persists, contact HP
Support personnel to troubleshoot the problem WBEM EventID: 302. WBEM
ProviderName: FPL_IndicationProviderWarning5173
Unsupported memory DIMM type. Probable Cause: A DIMM with an invalid DIMM
type was found Recommended Action: Contact HP Support personnel to troubleshoot
the problem WBEM EventID: 303. WBEM ProviderName: FPL_IndicationProviderWarning5174
The DIMM type of this DIMM doesn't match with others in the DIMM group. Probable
Cause: The DIMMs in the rank do not have the same DIMM type Recommended
Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID:
304. WBEM ProviderName: FPL_IndicationProviderWarning5175
The DIMM type table is full. New DIMM type cannot be added. Probable Cause: Too
many different types of DIMMs in system Recommended Action: Reduce the number
of different types of DIMMs in the system. WBEM EventID: 305. WBEM
ProviderName: FPL_IndicationProviderWarning5176
DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error
Recommended Action: Reload System Firmware Recommended Action: Contact HP
Support personnel to troubleshoot the problem WBEM EventID: 306. WBEM
ProviderName: FPL_IndicationProviderWarning5179