HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
The DIMM Loading Order check was bypassed. Probable Cause: Control bit to skip
DIMM loading order check is set. Recommended Action: Clear NVM Recommended
Action: Update PDC Recommended Action: Contact HP support to troubleshoot the
problem WBEM EventID: 334. WBEM ProviderName: FPL_IndicationProviderWarning5252
Looping on destructive memory tests. Probable Cause: Control bit to loop on
destructive memory test is set. Recommended Action: Clear NVM Recommended
Action: Update PDC Recommended Action: Contact HP support to troubleshoot the
problem WBEM EventID: 335. WBEM ProviderName: FPL_IndicationProviderWarning5253
DIMM Set Check has been skipped. Probable Cause: Control bit to skip DIMM set
check is set. Recommended Action: Clear NVM Recommended Action: Update PDC
Recommended Action: Contact HP support to troubleshoot the problem WBEM
EventID: 336. WBEM ProviderName: FPL_IndicationProviderWarning5255
Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip
DIMM SPD check is set. Recommended Action: Clear NVM Recommended Action:
Update PDC Recommended Action: Contact HP support to troubleshoot the problem
WBEM EventID: 337. WBEM ProviderName: FPL_IndicationProviderWarning5256
An Alternate Memory Config has been loaded into the system. Probable Cause:
Control bit to use an alternate memory config are set. Recommended Action: Clear
NVM Update SFW Contact HP support to troubleshoot the problem WBEM EventID:
338. WBEM ProviderName: FPL_IndicationProviderWarning5257
OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT
vector. Recommended Action: No action is required. The OS has failed to register
the vector or has chosen not to. WBEM EventID: 340. WBEM ProviderName:
FPL_IndicationProviderWarning5260
OS MCA address not registered. Probable Cause: The OS has not registered an
OS_MCA vector. Recommended Action: None, the OS has failed to register the vector
or has chosen not to. WBEM EventID: 341. WBEM ProviderName:
FPL_IndicationProviderWarning5263
OS MCA did not correct the Machine Check. Probable Cause: Uncorrected Machine
Check. Recommended Action: Analyze cause of Machine Check using diagnostic
and EFI tools. WBEM EventID: 342. WBEM ProviderName: FPL_IndicationProviderWarning5264
Found bad miscellaneous register. Probable Cause: A PDH register has failed.
Recommended Action: Reboot if necessary, if problem persists contact your HP
representative for support. WBEM EventID: 343. WBEM ProviderName:
FPL_IndicationProviderError5266
SAL_CHECK failed for an unknown reason. Probable Cause: The handler for
SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if
necessary, if problem persists contact your HP representative for support. WBEM
EventID: 344. WBEM ProviderName: FPL_IndicationProviderWarning5268
SAL_INIT failed for an unknown reason. Probable Cause: The handler for SAL_INIT
has failed for an unknown reason. Recommended Action: Reboot if necessary, if
problem persists contact your HP representative for support. WBEM EventID: 345.
WBEM ProviderName: FPL_IndicationProviderWarning5270
Unspecified memory interleave error. Probable Cause: FW encountered a fatal
interleaving error. Recommended Action: Update SFW Recommended Action: Contact
HP support to troubleshoot the problem WBEM EventID: 346. WBEM ProviderName:
FPL_IndicationProviderWarning5278
Unexpected return to SAL_CHECK. Probable Cause: Unexpected return to
SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 347. WBEM ProviderName:
FPL_IndicationProviderError5279
Unexpected return to SAL_INIT. Probable Cause: SAL_INIT has been unexpectedly
returned to. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 348. WBEM ProviderName:
FPL_IndicationProviderError5280
22 WBEM Provider Event Tables