HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
A CPU has taken over for the monarch CPU. Probable Cause: The previous monarch
may be suspect. WBEM EventID: 365. WBEM ProviderName: FPL_IndicationProviderError5411
Sram cannot be used on the cell. Probable Cause: SRAM cannot be located or used
on the cell board. Replace the cell board. WBEM EventID: 366. WBEM ProviderName:
FPL_IndicationProviderError5416
The dillon hardware cannot be located. Probable Cause: ROM is corrupt. Replace
the rom or reprogram flash. WBEM EventID: 367. WBEM ProviderName:
FPL_IndicationProviderError5417
A required piece of PDH bus hardware cannot be contacted. Probable Cause: Verify
all connections of PDH bus components or replace the cell board. WBEM EventID:
368. WBEM ProviderName: FPL_IndicationProviderError5418
Error: PCI Buses are configured for multiple speeds. Probable Cause: A PCI card is
configured with mixed speeds. Recommended Action: Correct the configuration
problem. WBEM EventID: 2420. WBEM ProviderName: FPL_IndicationProviderWarning5419
The bus depth was exceeded during IO probing. Probable Cause: Too many PCI
bridge cards are configured in single PCI segment mode. Recommended Action:
Reconfigure PCI cards and remove some of the bridge devices. WBEM EventID: 2421.
WBEM ProviderName: FPL_IndicationProviderError5420
A Timeout occurred during RI initialization. The CSR is in the data field. The alert
level will vary. Probable Cause: Hardware problem such as cable connect error or
bad cables. Recommended Action: Correct the hardware problem and re-boot. WBEM
EventID: 2422. WBEM ProviderName: FPL_IndicationProviderError5432
SuperIO has been detected in slot. Probable Cause: SuperIO has been detected in the
PCI slot. Recommended Action: No action required, information only. WBEM
EventID: 2423. WBEM ProviderName: FPL_IndicationProviderWarning5438
IO Link software error was corrected. Probable Cause: IO link error was detected
and corrected. Recommended Action: No action required, information only. WBEM
EventID: 372. WBEM ProviderName: FPL_IndicationProviderWarning5440
Parity error in Reg FIFO Internal parity error. Probable Cause: Parity error in Reg
FIFO. Recommended Action: Replace bad hardware. WBEM EventID: 374. WBEM
ProviderName: FPL_IndicationProviderError5442
TLB Fetch timeout. Probable Cause: SBA TLB fetch timeout error. Recommended
Action: Replace faulty hardware. WBEM EventID: 375. WBEM ProviderName:
FPL_IndicationProviderError5443
Link presence goes away, FE. Probable Cause: Link presence lost on SBA interface.
Recommended Action: Replace faulty hardware. WBEM EventID: 376. WBEM
ProviderName: FPL_IndicationProviderError5444
Elroy to REO parity error on command, rope will go fatal. Probable Cause: Bad
hardware. Recommended Action: Replace I/O chassis. WBEM EventID: 377. WBEM
ProviderName: FPL_IndicationProviderError5445
Access to invalid TLB entry Requesting rope fatal. Probable Cause: An IO device is
requesting access to an invalid TLB entry. Recommended Action: Driver problem -
debug driver. WBEM EventID: 378. WBEM ProviderName: FPL_IndicationProviderError5446
Memory fetch timeout. Probable Cause: SBA memory fetch timeout error
Recommended Action: repair faulty hardware WBEM EventID: 379. WBEM
ProviderName: FPL_IndicationProviderError5447
Error was encountered when Initializing the LBA. Probable Cause: LBA firmware
initialization failed Recommended Action: Review additional error logs to determine
exact cause of failure. WBEM EventID: 380. WBEM ProviderName:
FPL_IndicationProviderError5448