Event DescriptionEvent SeverityEvent ID
Failure to install a Partition level PDT. Probable Cause: Reset WBEM EventID: 400.
WBEM ProviderName: FPL_IndicationProviderError5485
A critical resource could not be found or is unusable. Probable Cause: Determine the
failing component or hardware from the data field as described and replace. WBEM
EventID: 401. WBEM ProviderName: FPL_IndicationProviderError5490
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
402. WBEM ProviderName: FPL_IndicationProviderError5491
NVRam test failed with a data compare error. Probable Cause: Bad NVRam, replace
the bad chip. WBEM EventID: 2426. WBEM ProviderName: FPL_IndicationProviderError5492
An NVRam CRC Error was detected. Probable Cause: Firmware/software error
Recommended Action: Check for new version of firmware/OS Contact HP Support
WBEM EventID: 2427. WBEM ProviderName: FPL_IndicationProviderError5493
The Error Response Mode has been determined. Probable Cause: Decode the hex
vales to ASCII to determine the mode. Other errors will determine action. WBEM
EventID: 4523. WBEM ProviderName: FPL_IndicationProviderWarning5494
A semaphore could not be obtained. Probable Cause: Recommended Action: Reset
system to clear the semaphore Try reinitializing NVRAM. If problem persists, contact
engineering. WBEM EventID: 405. WBEM ProviderName: FPL_IndicationProviderError5496
The BLOCK requested in NVRAM has the wrong revision. Probable Cause: Clear
NVRAM and reset. WBEM EventID: 2428. WBEM ProviderName:
FPL_IndicationProviderError5498
The requested NVRAM block was not found. Probable Cause: No Action Required.
Firmware can allocated space for the block. WBEM EventID: 407. WBEM
ProviderName: FPL_IndicationProviderWarning5499
The requested NVRAM block is locked. Probable Cause: Retry the operation. WBEM
EventID: 408. WBEM ProviderName: FPL_IndicationProviderWarning5500
Firmware tried to unlock a NVRAM block that was already unlocked. Probable
Cause: No action required. WBEM EventID: 409. WBEM ProviderName:
FPL_IndicationProviderWarning5501
The Header in NVRAM was not found. Probable Cause: NVRAM cannot be used. It
must be initialized first. Firmware will attempt the initialization. WBEM EventID:
410. WBEM ProviderName: FPL_IndicationProviderError5502
The Freelist used for NVM block allocation is corrupt. Probable Cause: Band NVRAM/
reinitialize. WBEM EventID: 411. WBEM ProviderName: FPL_IndicationProviderError5503
Firmware is preparing to reset for reconfiguration. Probable Cause: This can be caused
by many conditions including a bad complex profile, a bad hardware configuration,
a cell arriving late to the rendezvous point. A cell not being able to rendezvous.
Reconfiguration from partition manager is recommended. WBEM EventID: 412.
WBEM ProviderName: FPL_IndicationProviderError5505
An error was encountered communicating with utilities during PD rendez. Probable
Cause: Verify communications with the utilities system. WBEM EventID: 413. WBEM
ProviderName: FPL_IndicationProviderError5507
Forward Progress is stopping. The Cell or System will not boot further. Probable
Cause: An error occurred which triggered system firmware to cease making forward
progress. The CPU is put into a spin loop so that external debugging can take place.
See earlier event ids to help determine the cause of the error. Also note that the Error
Response Mode is likely to have directed firmware to HALT. WBEM EventID: 414.
WBEM ProviderName: FPL_IndicationProviderError5509
No console is available for the DUI to use. Probable Cause: DUI was entered before
the console is available. DUI will exit and processing will continue. WBEM EventID:
415. WBEM ProviderName: FPL_IndicationProviderWarning5510