Event DescriptionEvent SeverityEvent ID
Error Processing encountered an unrecoverable error. Probable Cause: Decode the
ASCII message and correct the problem. WBEM EventID: 416. WBEM ProviderName:
FPL_IndicationProviderError5511
System is unable to complete the Reset For Reconfiguration request. Probable Cause:
Delay the request for reconfiguration until after the PD has been released from Sinc
BIB. WBEM EventID: 417. WBEM ProviderName: FPL_IndicationProviderError5514
The cell is not able to reach all requested cells through the fabric. Probable Cause:
Fabric wasn't able to route to all cells described in the complex profile correctly due
to a hardware problem. Some of the cells are unreachable. Update the complex profile
or correct the hardware problem. WBEM EventID: 418. WBEM ProviderName:
FPL_IndicationProviderError5515
LBA has unexpected number of I/O Slots. Probable Cause: Unsupported I/O
configuration. Recommended Action: Remove the I/O cards below the specified
PCI-to-PCI bridge. WBEM EventID: 419. WBEM ProviderName:
FPL_IndicationProviderWarning5518
Console device failed to connect. Probable Cause: Debugging event, not for release.
WBEM EventID: 420. WBEM ProviderName: FPL_IndicationProviderError5521
Copying memory test code failed. Probable Cause: Memory test code located in main
memory has been corrupted Recommended Action: Contact HP support personnel
to troubleshoot the problem WBEM EventID: 421. WBEM ProviderName:
FPL_IndicationProviderWarning5525
A remote cell is in an unknown state of PD rendezvous. Probable Cause: Reset the
PD. WBEM EventID: 2430. WBEM ProviderName: FPL_IndicationProviderError5527
Multiple Core Cells have been discovered in the same PD. Probable Cause: Verify
that the complex profile is correct and reset the partition. WBEM EventID: 423. WBEM
ProviderName: FPL_IndicationProviderError5528
The utilities component encountered an error when sending a command to the MP.
Probable Cause: Verify the utilities system is connected correctly and reset. WBEM
EventID: 424. WBEM ProviderName: FPL_IndicationProviderError5529
Error received after issuing the Retrieve Cell Slot State command. Probable Cause:
Make sure the GSP is connected and reset. WBEM EventID: 1007. WBEM
ProviderName: FPL_IndicationProviderWarning5530
This indicates that all the cpus in the cell did not rendezvous during the MCA.
Probable Cause: When this happens the cell will step through some of the error
logging code on its own and then reset itself. WBEM EventID: 426. WBEM
ProviderName: FPL_IndicationProviderError5546
This indicates that it does not have any access to the PD. Probable Cause: Forward
Progress indicator; the cell will independently step through the error logging steps
before it resets itself. WBEM EventID: 427. WBEM ProviderName:
FPL_IndicationProviderError5547
This indicates the loss of lockstep during the MCA path. Probable Cause: The cell
will take up a few more error logging steps independently before resetting itself.
WBEM EventID: 428. WBEM ProviderName: FPL_IndicationProviderError5548
The PD level cell rendezvous failed. Probable Cause: This means that the cells will
independently step through some of the error logging code and then reset themselves.
WBEM EventID: 429. WBEM ProviderName: FPL_IndicationProviderError5550
It stands for diagnosis of catastrophic errors in the PIN block of concorde. Probable
Cause: This means that the cell will be reset. WBEM EventID: 557. WBEM
ProviderName: FPL_IndicationProviderError5556
The cell monarch cpu has failed. Probable Cause: The monarch cpu will be
deconfigured. WBEM EventID: 1020. WBEM ProviderName: FPL_IndicationProviderError5557