HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
This indicates that the cell missed the rendezvous at the partition level. Probable
Cause: The cell will independently step through some of the error logging steps and
then finally reset itself. WBEM EventID: 559. WBEM ProviderName:
FPL_IndicationProviderError5558
This means that the PD monarch timedout. Probable Cause: The cell will be reset ;
also the partition will be reset. WBEM EventID: 560. WBEM ProviderName:
FPL_IndicationProviderError5559
SetViewRoot on a remote cell failed. Probable Cause: Inter Processor interrupts failed.
Be sure that the partition rendezvous was successfully completed. Reset. WBEM
EventID: 2452. WBEM ProviderName: FPL_IndicationProviderError5560
Failed to update CSR contents. Probable Cause: Coherency controller on cell sending
event is suspect. Recommended Action: Provide event data to HP support center for
assistance. WBEM EventID: 2431. WBEM ProviderName: FPL_IndicationProviderError5566
This indicates the failure in collecting the Complex profile info. Probable Cause: The
partition level memory interleaving cannot continue without the appropriate
information. WBEM EventID: 563. WBEM ProviderName: FPL_IndicationProviderError5567
This chassis code indicates the failure in collecting the cell info. Probable Cause: The
partition level memory will fail. WBEM EventID: 564. WBEM ProviderName:
FPL_IndicationProviderError5568
This indicates the failure in updating the GNI info of the cell with CLM. Probable
Cause: The partition level memory will fail at this point. WBEM EventID: 565. WBEM
ProviderName: FPL_IndicationProviderError5569
This indicates the failure in adjusting the mem info with Minimum ZI req. Probable
Cause: This will cause the partition level memory to exit cell interleaving. WBEM
EventID: 566. WBEM ProviderName: FPL_IndicationProviderError5570
Complex Profile A has a checksum error. Probable Cause: Reconfigure the system
get a new complex profile distributed and reset. WBEM EventID: 2453. WBEM
ProviderName: FPL_IndicationProviderError5572
A Checksum error was encountered in the dynamic profile. Probable Cause: Push
out a new complex profile and reset. WBEM EventID: 1861. WBEM ProviderName:
FPL_IndicationProviderWarning5573
A checksum error occurred on the Partition Profile. Probable Cause: Push out a new
complex profile and reboot. WBEM EventID: 1862. WBEM ProviderName:
FPL_IndicationProviderWarning5574
The Stable Complex Profile Sequence Id is invalid. Probable Cause: Push out a new
complex profile and reset the system. The cell will be waiting for reconfiguration.
WBEM EventID: 2454. WBEM ProviderName: FPL_IndicationProviderError5575
The Dynamic Complex Profile Sequence ID is invalid. Probable Cause: Push out a
new complex profile. WBEM EventID: 2455. WBEM ProviderName:
FPL_IndicationProviderWarning5577
The Partition Profile Sequence ID is invalid. Probable Cause: Push out a new complex
profile and reset. The cell will be waiting for reconfiguration. WBEM EventID: 2456.
WBEM ProviderName: FPL_IndicationProviderError5578
Internal Firmware Programming Error from the EFI portion of the firmware. Probable
Cause: Report the IPF to the firmware team. Reset the system. This cannot be worked
around in the field. WBEM EventID: 570. WBEM ProviderName:
FPL_IndicationProviderError5579
The PD numbers in Group A and Group C of the complex profile are inconsistent.
Probable Cause: Push out consistent Complex profiles and reset the system. The cell
will be waiting for reconfiguration. WBEM EventID: 2457. WBEM ProviderName:
FPL_IndicationProviderError5580
28 WBEM Provider Event Tables