HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
PAL B execution rom warning. Probable Cause: PAL_B_ROM has generated a
warning. Recommended Action: Reboot, update SFW if necessary, if problem persists
contact your HP representative for support. WBEM EventID: 588. WBEM
ProviderName: FPL_IndicationProviderWarning5606
An error was encountered when firmware tried to update the Group B Profile.
Probable Cause: Utilities may be unavailable to update the profiles. Check the
connections are reset. WBEM EventID: 1030. WBEM ProviderName:
FPL_IndicationProviderError5607
PCI parity error detected. Probable Cause: I/O bus parity error. Recommended Action:
Consult the error logs for additional information. Determine and replace the failed
I/O device. WBEM EventID: 430. WBEM ProviderName: FPL_IndicationProviderWarning5617
PCI system error detected. Probable Cause: I/O device failure. Recommended Action:
Consult the error logs for additional information. Determine and replace the failed
I/O device. WBEM EventID: 431. WBEM ProviderName: FPL_IndicationProviderWarning5618
I/O host bridge is deconfigured. Probable Cause: See earlier error event.
Recommended Action: See earlier error event. WBEM EventID: 432. WBEM
ProviderName: FPL_IndicationProviderWarning5619
Firmware was unable to publish the Partition Profile. Probable Cause: Utilities may
be unavailable to update the profiles. Check the connections are reset. WBEM EventID:
1008. WBEM ProviderName: FPL_IndicationProviderError5621
The reporting cell is not configured to be in a PD. Probable Cause: Run parmgr to
configure the cell into a PD and reset the PD or add the cell. WBEM EventID: 434.
WBEM ProviderName: FPL_IndicationProviderError5622
DIMM thermal loading order warning. Probable Cause: The current DIMM loading
order does not follow the guidelines in the user manual Recommended Action:
Rearrange the DIMMs to follow the loading order specified in the Maintenance and
Operation Manual WBEM EventID: 435. WBEM ProviderName:
FPL_IndicationProviderWarning5623
The PD cannot boot, a majority of cells did not arrive at Rendezvous. Probable Cause:
PD Rendezvous Boot Rules: If greater than 50% of the assigned cells are rendezvoused,
we will boot. If less than 50% of the assigned cells are rendezvoused, don't boot. If
exactly 50% of the assigned cells are rendezvoused, including all of the preferred
core cells, we will boot. If exactly 50% have rendezvoused, and there is a specified
preferred core cell not rendezvoused, don't boot. If exactly 50% have rendezvoused,
and there are no preferred core cells, don't boot. If any of the above apply in
preventing the boot. Reconfigure the PD and reboot. WBEM EventID: 437. WBEM
ProviderName: FPL_IndicationProviderError5626
INIT: Monarch failed in slave rendezvous. Probable Cause: A processor has failed
rendezvous. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 439. WBEM ProviderName:
FPL_IndicationProviderWarning5638
MC: I/O error log/clear error. Probable Cause: SFW's Machine Check Handler was
unable to log or clear I/O error registers. Recommended Action: Reboot if necessary,
if problem persists contact your HP representative for support. WBEM EventID: 440.
WBEM ProviderName: FPL_IndicationProviderWarning5646
MC: MCA to BERR escalation not supported by PAL. Probable Cause: Cannot escalate
an MCA to BERR. Recommended Action: Analyze Machine Check Logs using
diagnostic tools and EFI tools. WBEM EventID: 441. WBEM ProviderName:
FPL_IndicationProviderWarning5655
MC: MCA to BINIT escalation not supported by PAL. Probable Cause: Cannot escalate
an MCA to BINIT. Recommended Action: Analyze Machine Check Logs using
diagnostic tools and EFI tools. WBEM EventID: 442. WBEM ProviderName:
FPL_IndicationProviderWarning5656
30 WBEM Provider Event Tables