HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
An unexpected or invalid value was read from a crossbar remote route table. Probable
Cause: An XBC is indicating a port failure Recommended Action: Validate all of the
cells connectivity to the PDCheck the XBC chips seating reset the system replace
either cells/system backplane WBEM EventID: 527. WBEM ProviderName:
FPL_IndicationProviderError5793
Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible
bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link
specified in the event data. Reset cell. WBEM EventID: 528. WBEM ProviderName:
FPL_IndicationProviderError5794
memory DIMM quad mis-match. Probable Cause: The user installed a mismatched
quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in quads of DIMMs that are the same
size and DRAM width. WBEM EventID: 529. WBEM ProviderName:
FPL_IndicationProviderWarning5795
Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected
excessive errors on the DIMM / Replace the specified DIMM WBEM EventID: 530.
WBEM ProviderName: FPL_IndicationProviderWarning5796
The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible
firmware or link error. Recommended Action: Check XBC and port specified by event
data. WBEM EventID: 531. WBEM ProviderName: FPL_IndicationProviderError5797
An error occurred while trying to read the PORT_STATUS CSR for a XBC port.
Probable Cause: Possible bad connection between cell and backplane. Recommended
Action: Check for hardware errors. Reset cell. WBEM EventID: 532. WBEM
ProviderName: FPL_IndicationProviderError5798
A XBC port was unexpectedly found to be landmined. Probable Cause: No action
required. WBEM EventID: 533. WBEM ProviderName: FPL_IndicationProviderError5799
CPUs running at different speeds were detected during rendezvous. Probable Cause:
Reconfigure the PD so that all cells have processors running at the same speed. WBEM
EventID: 1016. WBEM ProviderName: FPL_IndicationProviderError5800
The link between the local CC and the local XBC is unexpectedly not initialized.
Probable Cause: An error initializing fabric Recommended Action: A previously
reported event may provide exact detailsReboot, if failure persists, then either replace
the CC chip or the system backplane. WBEM EventID: 535. WBEM ProviderName:
FPL_IndicationProviderError5802
An invalid XBC number was given. Probable Cause: Firmware error Recommended
Action: Reset cell WBEM EventID: 536. WBEM ProviderName:
FPL_IndicationProviderError5803
An invalid XBC port number was given. Probable Cause: Firmware error
Recommended Action: Reset cell WBEM EventID: 537. WBEM ProviderName:
FPL_IndicationProviderError5804
A bad parameter was passed to the LED function in the utilities component. Probable
Cause: Contact FW engineering. This is a bug. WBEM EventID: 2464. WBEM
ProviderName: FPL_IndicationProviderWarning5805
An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. WBEM EventID: 539. WBEM ProviderName: FPL_IndicationProviderError5806
A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error.
Recommended Action: Reset cell WBEM EventID: 540. WBEM ProviderName:
FPL_IndicationProviderError5807
A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause:
Firmware error. Recommended Action: Reset cell. WBEM EventID: 541. WBEM
ProviderName: FPL_IndicationProviderError5808
Platform Events 37