HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
CPUs loaded in wrong order. Probable Cause: CPUs not loaded in correct order.
Recommended Action: Load CPUs in order 0, 1, 2, 3. WBEM EventID: 615. WBEM
ProviderName: FPL_IndicationProviderError7953
The XBC SBE and LPE errors were not cleared properly. Probable Cause: the link
generated a new error Recommended Action: check CC, check link Check logs for
other errors. If error is persistent, replace cell board WBEM EventID: 1031. WBEM
ProviderName: FPL_IndicationProviderError7963
The CC to XBC link pattern test failed. Probable Cause: Unspecified WBEM EventID:
2438. WBEM ProviderName: FPL_IndicationProviderError7964
Error Reading a platform storage variable from the PDHC/MP. Probable Cause:
Either the MP is not present, or the requested information does not exist. Ensure that
the MP is functioning and that the proper data is being requested. WBEM EventID:
616. WBEM ProviderName: FPL_IndicationProviderError7965
An error was returned on a Platform Storage Write Command to the PDHC/MP.
Probable Cause: The MP is not present, may be out of space, or the command was
badly formatted. Ensure that the MP has enough space and try again. If the problem
persists, contact engineering. WBEM EventID: 617. WBEM ProviderName:
FPL_IndicationProviderError7966
The Sequencer was unable to find/use a needed tree node. Probable Cause: This is a
bug, contact engineering WBEM EventID: 618. WBEM ProviderName:
FPL_IndicationProviderError7973
Firmware encountered an error in processing the partition variables. Probable Cause:
Either the GSP was not present or there was a resource problem storing the variable.
There should be other clues in the event id log to indicate which is the case. Restore
the GSP. WBEM EventID: 619. WBEM ProviderName: FPL_IndicationProviderError7974
A non-critical cell power fault has occurred. Probable Cause: A power converter has
failed. Recommended Action: Contact HP Support personnel to troubleshoot the
problem WBEM EventID: 620. WBEM ProviderName: FPL_IndicationProviderError7975
CPUProcConfigValue in /options is not compatible with the current PAL/CPU.
Probable Cause: Modify CPUProcConfigValue in /options to set the correct bits.
WBEM EventID: 2439. WBEM ProviderName: FPL_IndicationProviderError8009
Firmware was unable to determine the Processor Dependent Features. Probable
Cause: Contact Engineering, This is a bug. WBEM EventID: 622. WBEM
ProviderName: FPL_IndicationProviderWarning8010
Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. WBEM
EventID: 2434. WBEM ProviderName: FPL_IndicationProviderError8127
The CLU has encountered an undefined case. Probable Cause: CLU firmware on the
UGUY has gotten into an unexpected execution path, most likely due to a hardware
issue on the UGUY. Recommended Action: Check revision of CLU firmware. If out
of date, or known bad revision, use FWUU to update CLU firmware. Contact HP
Support personnel to troubleshoot problem WBEM EventID: 624. WBEM
ProviderName: FPL_IndicationProviderError8128
An unknown Cell voltage margin has been detected. Probable Cause: A user has
manually, using back-door debugging methods, altered the voltage margin setting
of one or more Cell Board or Cell Power Board converters. WBEM EventID: 625.
WBEM ProviderName: FPL_IndicationProviderWarning8130
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware or software in unknown state. Recommended Action: Upgrade PDHC
firmware to latest revision. If already at current revision, contact HP Support
personnel to troubleshoot the problem. WBEM EventID: 626. WBEM ProviderName:
FPL_IndicationProviderWarning8131
Platform Events 47