Event DescriptionEvent SeverityEvent ID
Boot is disabled because the cell type does not match the System FW ROM type.
Probable Cause: The cell's installed CPU modules do not all have the same type,
frequency and partition compatibility, so the Cell type cannot be accurately
determined. Recommended Action: Contact HP support personnel to troubleshoot
the mismatched CPU module WBEM EventID: 712. WBEM ProviderName:
FPL_IndicationProviderError8147
The PDHC has waited an abnormally long time for PDH bus access. Probable Cause:
A hardware fault is preventing the PDH arbiter from granting the PDHC control of
the bus. Recommended Action: Contact HP support personnel to troubleshoot the
cell board and/or PDH daughtercard. WBEM EventID: 713. WBEM ProviderName:
FPL_IndicationProviderWarning8149
The PDHC has waited an abnormally long time to obtain the PDH semaphore.
Probable Cause: A hardware fault is preventing the PDH bus semaphore from being
taken/released as expected. Recommended Action: Contact HP support personnel
to troubleshoot the Cell Board and/or PDH Daughtercard WBEM EventID: 714.
WBEM ProviderName: FPL_IndicationProviderWarning8151
An error occurred while transmitting an IPMI message in the BMC2HOST direction.
Probable Cause: A hardware fault is preventing the BMC2HOST queue from working.
Recommended Action: Contact HP support personnel to troubleshoot the PDH
Daughtercard. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProviderWarning8153
EFI unable to read initial debug level from the BMC. Probable Cause: SAL service to
read tokens not functioning properly. Recommended Action: Reset the system. Clear
SFW NVM. Upgrade system firmware. WBEM EventID: 716. WBEM ProviderName:
FPL_IndicationProviderWarning8154
A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC
is indicating a port failure Recommended Action: Validate all of the cells connectivity
to the PD Check the XBC chips seating reset the system replace either cells/system
backplane WBEM EventID: 717. WBEM ProviderName: FPL_IndicationProviderError8156
An invalid number of XBC ports were landmined in the system. Probable Cause:
Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for
hardware failures. Reset backplane to re-initialize fabric. WBEM EventID: 1033.
WBEM ProviderName: FPL_IndicationProviderError8159
The backplane was not recognized as one that contains fabric. Probable Cause: An
unrecognized backplane is installed. Recommended Action: Contact HP Support
Personnel to determine why the backplane was unrecognized. WBEM EventID: 719.
WBEM ProviderName: FPL_IndicationProviderError8184
Writing the XIN Error Mask Register to zero failed. Probable Cause: CC Write Failure.
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 720. WBEM ProviderName: FPL_IndicationProviderWarning8186
Dumping error info. Read status of the Primary Mode Register. Probable Cause: CC
to XBC link init failure. Contact your HP service representative to check the CC to
XBC link WBEM EventID: 1758. WBEM ProviderName: FPL_IndicationProviderError8187
Data read from the CC Primary Mode CSR. Probable Cause: CC to XBC link init
failure. Contact your HP service representative to check the CC to XBC link WBEM
EventID: 722. WBEM ProviderName: FPL_IndicationProviderError8188
Dumping error info. Read status of the CC Error Mask Register. Probable Cause: CC
to XBC link init failure. Contact your HP service representative to check the CC to
XBC link WBEM EventID: 723. WBEM ProviderName: FPL_IndicationProviderError8189
Data read from the CC Error Mask CSR. Probable Cause: CC to XBC link init failure.
Contact your HP service representative to check the CC to XBC link WBEM EventID:
724. WBEM ProviderName: FPL_IndicationProviderError8190
The link could not be crossed upon first attempt. Probable Cause: The neighbor port
is not routable. The port is either: not connected, landmined, in FE, or contains an
SBE or LPE. Recommended Action: Contact HP Support personnel to analyze the
fabric. WBEM EventID: 725. WBEM ProviderName: FPL_IndicationProviderWarning8194