HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
The System Flash Write Enable bit is incorrectly set and now clearing by PDC.
Probable Cause: The System Flash Write Enable bit is incorrectly set by hardware
and now cleared by PDC. Recommended Action: If this chassis code occurs in every
boot then contact HP Support personnel to troubleshoot the problem. WBEM EventID:
1764. WBEM ProviderName: FPL_IndicationProviderWarning8851
Firmware encountered a problem trying to initialize. Probable Cause: Examine the
related event that failed and correct that problem. WBEM EventID: 837. WBEM
ProviderName: FPL_IndicationProviderError8855
This means that all the cpus in the cell did not show up. Probable Cause: This will
result in the cell stepping independently to collect its logs and resting itself. WBEM
EventID: 838. WBEM ProviderName: FPL_IndicationProviderWarning8857
This means that all the cells did not rendezvous during the PD rendezvous. Probable
Cause: The cells will reset themselves. WBEM EventID: 839. WBEM ProviderName:
FPL_IndicationProviderWarning8858
The FW tree sanity check failed during the MCA error processing. Probable Cause:
The cells will independently log errors and reset. WBEM EventID: 840. WBEM
ProviderName: FPL_IndicationProviderWarning8859
This means that the registry sanity check failed during MCA error handling. Probable
Cause: The cells will independently log errors and reset. WBEM EventID: 841. WBEM
ProviderName: FPL_IndicationProviderWarning8860
This means that MCA occurred while OS_MCA was performing error recovery.
Probable Cause: The cells will log information and reset. WBEM EventID: 842. WBEM
ProviderName: FPL_IndicationProviderWarning8861
One of the BT errors occurred that results in abandoning memory dump. Probable
Cause: A machine check has occurred and cells have not rendezvoused. Recommended
Action: Cells will reset themselves. WBEM EventID: 843. WBEM ProviderName:
FPL_IndicationProviderWarning8864
The firmware tree is not complete and hence there will be no PD rendezvous. Probable
Cause: The cell will log errors and reset WBEM EventID: 844. WBEM ProviderName:
FPL_IndicationProviderWarning8865
ACPI configuration mismatch across cells in the partition. Probable Cause: Set the
ACPI configuration parameter again to ensure that all cells have a consistent value.
WBEM EventID: 845. WBEM ProviderName: FPL_IndicationProviderError8872
Failed clearing of the XIN_ERR_ORDER_STATUS CSR. Probable Cause: Failure to
access the register or the write did not work. Recommended Action: Contact HP
Support personnel to check the CC. WBEM EventID: 846. WBEM ProviderName:
FPL_IndicationProviderError8873
Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 848.
WBEM ProviderName: FPL_IndicationProviderWarning8876
Invalid data read from a CPU module's Processor Information ROM. Probable Cause:
The CPU module's Processor Information ROM is unprogrammed. Recommended
Action: Contact HP support personnel to troubleshoot the CPU module pointed to
by the physical location portion of this event. WBEM EventID: 849. WBEM
ProviderName: FPL_IndicationProviderWarning8877
Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid
parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProviderWarning8882
Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM
EventID: 851. WBEM ProviderName: FPL_IndicationProviderWarning8883
CC to CC link did not initialize on the local cell. Probable Cause: link failure between
the XBC and the CC Recommended Action: Check CC. WBEM EventID: 852. WBEM
ProviderName: FPL_IndicationProviderWarning8894
56 WBEM Provider Event Tables