HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Error while copying the XBC routing to the local port. Probable Cause: Error accessing
XBC CSRs. Recommended Action: Contact HP Support personnel to analyze the
fabric. WBEM EventID: 870. WBEM ProviderName: FPL_IndicationProviderError8959
A read after write of a XBC CSR failed. Probable Cause: Fabric Access Error, XBC
Key Disabled. Check XBC, links, backplane, Contact HP Support Personnel for further
troubleshooting. WBEM EventID: 871. WBEM ProviderName: FPL_IndicationProviderError8960
Couldn't release the Semaphore while writing routing states. Probable Cause: Fabric
Access Error. Check XBC, Check links. WBEM EventID: 872. WBEM ProviderName:
FPL_IndicationProviderWarning8962
Couldn't write the XBC's forward progress register. Probable Cause: Fabric Access
Error. Couldn't write this XBC. Recommended Action: Contact HP Support personnel
to analyze the fabric. WBEM EventID: 873. WBEM ProviderName:
FPL_IndicationProviderError8964
Couldn't access the XBC semaphore registers. Probable Cause: Fabric Access Error.
Couldn't read or write this XBC. Recommended Action: Contact HP Support personnel
to analyze the fabric. WBEM EventID: 874. WBEM ProviderName:
FPL_IndicationProviderError8965
Couldn't determine the complex fabric topology. Probable Cause: Fabric Access Error.
Couldn't write this XBC. Recommended Action: Contact HP Support personnel to
analyze the fabric. WBEM EventID: 875. WBEM ProviderName:
FPL_IndicationProviderError8966
Error checking a cell to cell link during traversability tests. Probable Cause: Probably
an error reading the XIN. Look for additional descriptive chassis codes. Recommended
Action: Contact HP Support personnel to check the CC WBEM EventID: 876. WBEM
ProviderName: FPL_IndicationProviderWarning8968
An error occurred while traversing the cell to cell link. Probable Cause: Probably an
error reading the XIN. Look for additional descriptive chassis codes. Recommended
Action: Contact HP Support personnel to check the CC WBEM EventID: 877. WBEM
ProviderName: FPL_IndicationProviderWarning8969
Error reading the local cell's XIN link state. Probable Cause: Hardware Access Error.
Have your HP support representative check the Coherency Controller (CC). WBEM
EventID: 878. WBEM ProviderName: FPL_IndicationProviderWarning8970
Error reading the remote cell's XIN link state register. Probable Cause: Hardware
Access Error. Have your HP support representative check the backplane and
Coherency Controller (CC). WBEM EventID: 879. WBEM ProviderName:
FPL_IndicationProviderWarning8971
The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are
connected. Check historical chassis codes from most recent boot to see if the link had
ever initialized. Have your HP support representative check the backplane and
Coherency Controller (CC). WBEM EventID: 880. WBEM ProviderName:
FPL_IndicationProviderWarning8972
The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are
connected. Check historical chassis codes from most recent boot to see if the link had
ever initialized. Have your HP support representative check the backplane and
Coherency Controller (CC). WBEM EventID: 881. WBEM ProviderName:
FPL_IndicationProviderWarning8973
Error reading the XIN_LINK_STATE register while disabling the link. Probable
Cause: Hardware Access Error. Recommended Action: Contact HP Support personnel
to analyze the fabric, CC, Backplane. WBEM EventID: 882. WBEM ProviderName:
FPL_IndicationProviderWarning8974
Error reading the XIN_LINK_STATE register. Probable Cause: link init problem
Recommended Action: Contact HP Support personnel to check the XBC, CC,
backplane WBEM EventID: 883. WBEM ProviderName: FPL_IndicationProviderError8975
58 WBEM Provider Event Tables