HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Cell about to be halted because PDC couldn't determine relocated address of code.
Probable Cause: Cell was unable to access its own PDH memory. Recommended
Action: Troubleshoot the cell board and replace it if necessary. WBEM EventID: 910.
WBEM ProviderName: FPL_IndicationProviderWarning9367
Halting cell because a CPU didn't complete the task for which it was awakened.
Probable Cause: Hardware problem with the CPU, CC, or PDH flash. Recommended
Action: Troubleshoot the cell and/or replace it. WBEM EventID: 911. WBEM
ProviderName: FPL_IndicationProviderWarning9368
Cell about to be halted because PDC couldn't determine relocated address of code.
Probable Cause: PDC bug such that PDC didn't log the relocation address.
Recommended Action: Check for PDC upgrade WBEM EventID: 912. WBEM
ProviderName: FPL_IndicationProviderWarning9370
Cell about to be halted because CPU couldn't change its CPU FP (PST) state. Probable
Cause: Hardware problem with the cell (like PDH memory) or the CC or CPU.
Recommended Action: Contact HP support to troubleshoot or replace the cell board.
WBEM EventID: 913. WBEM ProviderName: FPL_IndicationProviderWarning9371
Partition about to be reset because PDC couldn't get address to a structure. Probable
Cause: Hardware connecting cells in the partition experienced a problem such that
cells in the partition together can no longer communicate. Recommended Action:
Troubleshoot the fabric and replace backplane or cells. Gather event logs and contact
HP Customer Support for assistance. WBEM EventID: 914. WBEM ProviderName:
FPL_IndicationProviderError9372
Resetting a partition because a CPU didn't complete the task it was awakened for.
Probable Cause: Hardware problem with the CPU chip, CC chip, or PDH flash.
Recommended Action: Troubleshoot the cell and/or replace it. Contact HP Customer
Support for assistance. WBEM EventID: 915. WBEM ProviderName:
FPL_IndicationProviderError9373
Resetting partition because PDC couldn't determine relocated address of code.
Probable Cause: Cell was unable to access its own PDH memory. Recommended
Action: Troubleshoot the cell board and replace it if necessary. Contact HP Customer
Support for assistance. WBEM EventID: 916. WBEM ProviderName:
FPL_IndicationProviderError9375
Resetting partition because a CPU was unable to change its CPU FP state. Probable
Cause: Hardware problem with PDH memory, CC chip, or the CPU chip.
Recommended Action: Troubleshoot the cell and/or replace it. Contact HP Customer
Support for assistance. WBEM EventID: 917. WBEM ProviderName:
FPL_IndicationProviderError9376
CPU Dual Core Initialization Failed. Probable Cause: MX2 initialization failed
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 918. WBEM ProviderName: FPL_IndicationProviderWarning9379
Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual
Core has been deconfigured as a result of the first core being deconfigured.
Recommended Action: Investigate the cause of the first core being deconfigured
WBEM EventID: 919. WBEM ProviderName: FPL_IndicationProviderWarning9380
Virtualzing Dual Core Registers Failed. Probable Cause: FW failed to virtualize the
mx2 interposer. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 920. WBEM ProviderName:
FPL_IndicationProviderError9382
Virtualizing Dual Core Interposer has failed. Probable Cause: Virtualizing the Dual
Core Interposer has failed. Recommended Action: Reboot. If problem persists contact
your HP representative for support. WBEM EventID: 921. WBEM ProviderName:
FPL_IndicationProviderWarning9383
Install PMI Handler Failed. Probable Cause: Installation of the FW PMI handler has
failed. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 922. WBEM ProviderName:
FPL_IndicationProviderError9385