HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Cell failed compatibility checks. Probable Cause: A Cell or CPU module's FRU data
is programmed incorrectly. Recommended Action: If this is in manufacturing,
re-program the FRU specific field of the FRU data for the cell or CPU module.
Otherwise, contact HP Support personnel to troubleshoot the problem. WBEM
EventID: 923. WBEM ProviderName: FPL_IndicationProviderError9388
PDH space not available after release from reset. Probable Cause: A hardware fault
has occurred. Recommended Action: Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH Daughtercard. WBEM EventID: 924.
WBEM ProviderName: FPL_IndicationProviderError9389
MPON failed to release. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. WBEM EventID: 925. WBEM
ProviderName: FPL_IndicationProviderError9390
Dillon failed to reset. Probable Cause: Hardware failure. Recommended Action: Fix
the hardware, pdh riser or cell. WBEM EventID: 926. WBEM ProviderName:
FPL_IndicationProviderError9391
DMD clock is not running. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. WBEM EventID: 927. WBEM
ProviderName: FPL_IndicationProviderError9392
All cpus on the Cell are scheduled to be deconfigured. Probable Cause: All cpus on
the cell have been scheduled for deconfiguration. On the next reset, the cell will no
longer be operational; system firmware will deconfigure all the cpus and this cell
will not be part of a partition. This action is not recommended. To recover, the
NVRAM on the PDH card must be cleared, the cell power cycled, and defaults
restored from disk. WBEM EventID: 928. WBEM ProviderName:
FPL_IndicationProviderError9394
A read error occurred while dumping the routing registers. Probable Cause: Fabric
Read Error. Recommended Action: Check XBC, CC, links, etc. WBEM EventID: 929.
WBEM ProviderName: FPL_IndicationProviderError9403
Failed to disable the CC to CC link. Probable Cause: Failure to read or write CC CSRs.
Recommended Action: Contact HP Support personnel to check the Check CC. WBEM
EventID: 930. WBEM ProviderName: FPL_IndicationProviderError9412
Power has been removed from AC input A0. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 931. WBEM ProviderName:
FPL_IndicationProviderWarning9417
Power has been removed from AC input A1. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 932. WBEM ProviderName:
FPL_IndicationProviderWarning9418
Power has been removed from AC input B0. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 933. WBEM ProviderName:
FPL_IndicationProviderWarning9419
Power has been removed from AC input B1. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 934. WBEM ProviderName:
FPL_IndicationProviderWarning9420
Failed to disable the XIN link during a failed link init. Probable Cause: Have your
HP Support Representative check the Coherency Controller WBEM EventID: 935.
WBEM ProviderName: FPL_IndicationProviderWarning9428
Error copying the routing registers to the local port. Probable Cause: XBC access
failure. Recommended Action: Check XBC, check links, check backplane, check CC.
WBEM EventID: 1765. WBEM ProviderName: FPL_IndicationProviderError9430
Error while reading the remote CC's XIN Error Mask register. Probable Cause: CC
access failure. Recommended Action: Contact HP Support personnel to check the
CC. WBEM EventID: 937. WBEM ProviderName: FPL_IndicationProviderWarning9431
62 WBEM Provider Event Tables