HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Windows: Server Agents Management data not accessible, locked property. Probable
Cause: The installed management software has detected an unstable state of the
underlying IPMI (Intelligent Platform Management Interface) subsystem and has
disabled all management information from being shown by any manageability
applications. The management information will become available automatically as
soon as the IPMI subsystem has stabilized. Recommended Action: No action is
required. WBEM EventID: 1806. WBEM ProviderName: FPL_IndicationProviderWarning9653
PCI slot exceeds power limit. Probable Cause: The I/O configuration's power
consumption exceeds the supported limit. Recommended Action: Remove the I/O
card from each slot indicated by an IO_PCI_POWER_OVERLOAD_ERR event. WBEM
EventID: 976. WBEM ProviderName: FPL_IndicationProviderError9658
(warning) Outputted in MFG, when Memory SBE Seeding is enabled. Probable Cause:
In MFG with Memory SBE Seeding control Flag (26) Enabled. Should never be seen
at a customer's machine. WBEM EventID: 977. WBEM ProviderName:
FPL_IndicationProviderWarning9659
Failed to read the fabric topology information from the XBC. Probable Cause: Fabric
Access Failure. Recommended Action: Contact HP Support personnel to analyze the
fabric. WBEM EventID: 978. WBEM ProviderName: FPL_IndicationProviderError9661
PDC failed to initialize PA specific fields of group C after finding IA bit set. Probable
Cause: An error occurred which prevented the complex profiles from being distributed
properly. Recommended Action: Create and distribute a new complex profile using
ParMgr on a functional partition in the complex. Restore the last complex profile
using the 'CC' command from the MP, then use ParMgr to create a new complex
profile. Generate a genesis complex profile using the 'CC' command from the MP,
then use ParMgr to create a new complex profile. WBEM EventID: 1807. WBEM
ProviderName: FPL_IndicationProviderError9663
Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 1808.
WBEM ProviderName: FPL_IndicationProviderWarning9666
PDC could not read the copy of profile C stored in ICM. Probable Cause: An error
occurred which prevented the complex profiles from being distributed properly.
Recommended Action: Create and distribute a new complex profile using ParMgr
on a functional partition in the complex. Restore the last complex profile using the
'CC' command from the MP, then use ParMgr to create a new complex profile.
Generate a genesis complex profile using the 'CC' command from the MP, then use
ParMgr to create a new complex profile. WBEM EventID: 1809. WBEM ProviderName:
FPL_IndicationProviderError9668
Could not disable the XIN link before a fabricless boot. Probable Cause: Fabric Access
Error. Recommended Action: Contact HP Support personnel to check the CC, Check
XBC WBEM EventID: 981. WBEM ProviderName: FPL_IndicationProviderError9670
Fail to GetSiblingCpuCoreNum() in BootGetSpiromData(). Probable Cause: Hardware
problem with the CPU. Recommended Action: Contact HP Support to confirm the
CPU is functioning properly. WBEM EventID: 1810. WBEM ProviderName:
FPL_IndicationProviderWarning9674
The clock ratio reported by manageability does not match the actual clock ratio.
Probable Cause: This is a hardware error and it is fatal WBEM EventID: 2687. WBEM
ProviderName: FPL_IndicationProviderError9678
Manual override of fatal stop boot condition. Probable Cause: The user has initiated
manual O/S boot despite the existence of a error. Recommended Action: Correct the
error condition (see output of 'INFO WARNING' EFI shell command), reboot the
system, and then initiate O/S boot. WBEM EventID: 985. WBEM ProviderName:
FPL_IndicationProviderError9681
66 WBEM Provider Event Tables