HP Insight Manager WBEM Provider Events Reference
1 WBEM Provider Event Tables
Introduction
This reference guide describes the Windows System Log Event ID number, severity, and
description of events generated by HP Integrity WBEM provider software. The WBEM providers
are a group of services that run continuously in the background on HP Integrity servers and
report the status of system components. Each WBEM provider has its own unique table in this
document.
Each row in the Platform Events table includes the following information about the event:
• ID number in the Windows System Log (the table is sorted on this field, in ascending order)
• Severity (Warning or Error)
• Description, which includes the following information:
— a short description of the event
— probable cause of the event
— the recommended course of action
— the WBEM EventID that generated the event
— the WBEM provider name
Each row in the remaining WBEM provider event tables includes the following information
about the event:
• ID number in the Windows System Log (the table is sorted on this field, in ascending order)
• Severity (Informational, Warning, or Error)
• Description
Platform Events
Table #1 — Event ID numbers 0 through 8,999
Event DescriptionEvent SeverityEvent ID
A temperature inside the server has gone outside the factory specified range. Probable
Cause: The temperature inside the server has gone outside the factory specified range
for normal operation. You should quit applications and power down the server to
protect its hardware from damage. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors Recommended Action: Find cause of temperature
anomaly and fix it. WBEM EventID: 4. WBEM ProviderName:
FPL_IndicationProvider02Warning4
A temperature inside the server has gone far outside the factory specified range.
Probable Cause: The temperature inside the server has gone far outside the factory
specified range for normal operation. To avoid permanent damage to your server
hardware, go and turn off the server immediately. This event may indicate one of
the following conditions: a failed fan blocked air vents or poor ventilation around
the server open server chassis cover, or missing drive slot covers high temperature
in the room where the server resides an unusually hot hardware component located
near one of the server's temperature sensors Recommended Action: Find cause of
temperature anomaly and fix it. WBEM EventID: 5. WBEM ProviderName:
FPL_IndicationProvider02Error5
Introduction 7