HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Failed to copy the XBC CSR Error Symbol01 Block. Probable Cause: Fabric Access
Failure; Possibly an invalid destination address. Check hardware, Contact HP Support
WBEM EventID: 1833. WBEM ProviderName: FPL_IndicationProviderWarning9781
Failed to copy the XBC CSR Error Symbol23 Block. Probable Cause: Fabric Access
Failure; Possibly an invalid destination address. Check hardware, Contact HP Support
WBEM EventID: 1834. WBEM ProviderName: FPL_IndicationProviderWarning9782
Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Flex Cables, Backplane WBEM EventID: 1835. WBEM ProviderName:
FPL_IndicationProviderWarning9783
Failed to clear the XBC Low Severity Log Symbol 01. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Backplane WBEM EventID: 1836. WBEM ProviderName: FPL_IndicationProviderWarning9784
Could not determine if there is a new XBC CSR Low Severity error. Probable Cause:
Fabric Access Failure. Recommended Action: Contact HP Support personnel to check
the XBC, Flex Cables, Backplane WBEM EventID: 1837. WBEM ProviderName:
FPL_IndicationProviderWarning9785
Failed to read the XBC CSR Low Severity Error Log State. Probable Cause: Fabric
Access Failure. Recommended Action: Contact HP Support personnel to check the
XBC, Flex Cables, Backplane WBEM EventID: 1838. WBEM ProviderName:
FPL_IndicationProviderWarning9786
Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Flex Cables, Backplane WBEM EventID: 1839. WBEM ProviderName:
FPL_IndicationProviderWarning9787
Could not determine if there is a new XBC CSR High Severity error. Probable Cause:
Check XBC, Flex Cables, Backplane Recommended Action: Contact HP Support
personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1840. WBEM
ProviderName: FPL_IndicationProviderWarning9788
Failed to read the XBC CSR High Severity Error Log State. Probable Cause: Fabric
Access Failure. Recommended Action: Contact HP Support personnel to check the
XBC, Flex Cables, Backplane WBEM EventID: 1841. WBEM ProviderName:
FPL_IndicationProviderWarning9789
An error occurred while enabling hashing in the platform cache. Probable Cause: An
error return status. This could happen if the tree was corrupted or there was an error
verifying the hashing setting. Recommended Action: reset the partition WBEM
EventID: 1842. WBEM ProviderName: FPL_IndicationProviderError9801
The XBC CSR is not a valid CSR address. Probable Cause: Invalid CSR address,
possible firmware defect. Recommended Action: Capture complete live logs and
contact HP Support representative. WBEM EventID: 1843. WBEM ProviderName:
FPL_IndicationProviderWarning9827
It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to
cells performing RESET_FOR_RECONFIG after getting the error logs. WBEM EventID:
2448. WBEM ProviderName: FPL_IndicationProviderError9832
Error building cell-level FW device tree. Probable Cause: Data field displays the
status of creating the cell level device tree for use by firmware. See previous errors
already reported. WBEM EventID: 2450. WBEM ProviderName:
FPL_IndicationProviderError9849
CPU deconfigured during FSB interface initialization. Probable Cause: internal error.
Recommended Action: the CPU will be deconfigured. If the error persists after a
powercycle, contact HP Support. WBEM EventID: 1845. WBEM ProviderName:
FPL_IndicationProviderWarning9867
70 WBEM Provider Event Tables