HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
fabric API is about to open the a link going out of the local cell. Probable Cause: An
error prevented the use of a fabric link. Recommended Action: Collect IPMI event
logs for more information regarding the failure. Contact your HP Support
Representative to investigate the fabric subsystem. WBEM EventID: 2914. WBEM
ProviderName: FPL_IndicationProviderWarning10209
An Arches fabric CSR read was unsuccessful because of a timeout. Probable Cause:
An error occurred while reading a hardware register. Other events should detail the
error. Recommended Action: Contact your HP Support Representative to investigate
the fabric and firmware vertex modules. WBEM EventID: 2908. WBEM ProviderName:
FPL_IndicationProviderError10272
An Arches fabric CSR write was unsuccessful. Probable Cause: An error occurred
while writing a hardware register. Other events should detail the error. Recommended
Action: Contact your HP Support Representative to investigate the fabric and firmware
vertex modules. WBEM EventID: 2909. WBEM ProviderName:
FPL_IndicationProviderError10273
The event data details the error that was encountered. Probable Cause: A fabric error
occurred while preparing for rendezvous Recommended Action: Contact your HP
Support Representative to investigate the fabric and firmware vertex modules. WBEM
EventID: 2910. WBEM ProviderName: FPL_IndicationProviderError10343
The maximum memory supported by this system has been exceeded. Probable Cause:
Too much memory has been installed in the system. Recommended Action: Remove
DIMMs to get the total memory size below the amount of memory returned in the
data field WBEM EventID: 2911. WBEM ProviderName: FPL_IndicationProviderError10351
Failed to delete a bad port while routing the fabric. Data field indicates return status.
Probable Cause: Experienced an error while routing the fabric. Recommended Action:
Contact your HP Support Representative to investigate the fabric and firmware vertex
modules. WBEM EventID: 4848. WBEM ProviderName: FPL_IndicationProviderWarning10357
Failed to delete an edge that was found to be bad during routing. Probable Cause:
Experienced an error while routing the fabric. Recommended Action: Contact your
HP Support Representative to investigate the fabric and firmware vertex modules.
WBEM EventID: 4849. WBEM ProviderName: FPL_IndicationProviderWarning10358
A command to the memory buffer chip failed to complete. Probable Cause: System
firmware did not get a completion status from a command to a memory buffer chip.
Recommended Action: Contact HP support. WBEM EventID: 2917. WBEM
ProviderName: FPL_IndicationProviderError10361
The Arches Fabric function ArfIsCsrRouteTraversable was called for a back-to-back
system. This is unsupported, ArfIsCsrRouteTraversable should only be called for
systems with crossbars. No data. Probable Cause: An unsupported fabric call was
made. Recommended Action: Contact your HP Support Representative to investigate
the fabric and firmware vertex modules. WBEM EventID: 2918. WBEM ProviderName:
FPL_IndicationProviderWarning10375
An invalid port number was given as an input to an Arches Fabric Traversability
function. The port is expected to be an internal XBC num (8-15), but the actual port
was not. Data field: (XBC number 32) | (port number 48). Probable Cause: Internal
firmware error. Recommended Action: Contact your HP Support Representative to
investigate the fabric and firmware vertex modules. WBEM EventID: 2919. WBEM
ProviderName: FPL_IndicationProviderWarning10376
Unable to read XBC port neighbor information. Data field: (xbcNum 32) | (portNum
48). Probable Cause: System firmware was unable to read a fabric hardware register.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric WBEM EventID: 2920. WBEM
ProviderName: FPL_IndicationProviderWarning10377
Platform Events 73