HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data
field: (data written to CSR) | (actual CSR data read 32). Probable Cause: System
firmware was unable to write a fabric hardware register. Recommended Action:
Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric WBEM EventID: 2952. WBEM ProviderName:
FPL_IndicationProviderWarning10414
SetupNCTable failed in ArfPhase3. Data field: cell set passed in to SetupNCTable.
Probable Cause: System firmware was unable to write some fabric hardware registers.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric WBEM EventID: 2953. WBEM
ProviderName: FPL_IndicationProviderWarning10415
A failure occurred while prepping a back-to-back system for post-rendezvous Arches
Fabric setup. Data field: return value from Phase4BackToBackPrep. Probable Cause:
System firmware was unable to write various fabric hardware registers.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric WBEM EventID: 2954. WBEM
ProviderName: FPL_IndicationProviderWarning10427
ArfPhase4 was unable to set up the Non-Coherent link select to at least one cell in
its alive/gsm sharing set. Data field: bitmap of unreachable cells. Probable Cause:
System firmware was unable to find valid routes to each cell in a previously good
partition. Possible cable/connection problems. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric WBEM EventID: 2955. WBEM ProviderName:
FPL_IndicationProviderWarning10429
Unable to set the Non-Coherent route. Data field: (sourceCell 32) | (cell set passed
in to SetupNCTable). Probable Cause: System firmware was unable to write various
fabric hardware registers. Recommended Action: Capture IPMI event logs, look for
additional errors. Contact your HP Support Representative to analyze the fabric
WBEM EventID: 2956. WBEM ProviderName: FPL_IndicationProviderWarning10431
Unable to setup the Coherent route table for a cell in our partition. Data field:
(sourceCell 32) | (cell set passed in to SetupCohTable). Probable Cause: System
firmware was unable to write various fabric hardware registers. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric WBEM EventID: 2957. WBEM ProviderName:
FPL_IndicationProviderWarning10432
Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set
to disable) | (xbcNum 32) | (xbc port 48). Probable Cause: System firmware was
unable to write various fabric hardware registers. Recommended Action: Capture
IPMI event logs, look for additional errors. Contact your HP Support Representative
to analyze the fabric WBEM EventID: 2958. WBEM ProviderName:
FPL_IndicationProviderWarning10435
The Arches Fabric vertex module returned an unexpected error during Non-Coherent
table setup. Data field: (return value) | (sourceCell 32) | (dest cell 48). Probable Cause:
Internal firmware error or data corruption. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric WBEM EventID: 2959. WBEM ProviderName:
FPL_IndicationProviderWarning10436
A write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of
the Skyline that failed. Probable Cause: System firmware was unable to write a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric WBEM EventID:
2960. WBEM ProviderName: FPL_IndicationProviderWarning10439
Unable to write the XBC port scratch CSR with the routing state. Data field: (routing
state) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable
to write a fabric hardware register. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric WBEM EventID: 2962. WBEM ProviderName: FPL_IndicationProviderWarning10475
Platform Events 77