HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| return status. Probable Cause: An error occurred while routing the fabric
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 4873. WBEM ProviderName:
FPL_IndicationProviderWarning11040
An invalid port number was returned when selecting a route for the XBC-CC link.
Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected. Probable
Cause: An error occurred while routing the fabric Recommended Action: Contact
your HP support representative to inspect the fabric and system firmware.Warning11041
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| switch fabric. Probable Cause: An error occurred while routing the fabric
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 4875. WBEM ProviderName:
FPL_IndicationProviderWarning11042
The second flash part is not programmed with a valid image. WBEM EventID: 7212.
WBEM ProviderName: FPL_IndicationProviderWarning11052
System backplane power has reported a 1.2v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 1.2v LDO fault. Recommended Action: Check system backplane. WBEM
EventID: 4906. WBEM ProviderName: FPL_IndicationProviderError11452
System backplane power has reported a 2.5v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 2.5v LDO fault. Recommended Action: Check system backplane. WBEM
EventID: 4907. WBEM ProviderName: FPL_IndicationProviderError11454
System backplane power has reported a 3.3v house keeping power fault. The data
field contains the physical location of the fault. Probable Cause: System backplane
power board has reported a 3.3v house keeping fault. Recommended Action: Check
system backplane power board. WBEM EventID: 4908. WBEM ProviderName:
FPL_IndicationProviderError11456
System backplane power has reported a 12v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 12v fault. Recommended Action: Check system backplane power board.
WBEM EventID: 4909. WBEM ProviderName: FPL_IndicationProviderError11459
System backplane power has reported a 3.3v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 3.3v fault. Recommended Action: Check system backplane power board.
WBEM EventID: 4910. WBEM ProviderName: FPL_IndicationProviderError11461
System backplane power has reported a 1.5v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 1.5v fault. Recommended Action: Check system backplane power board.
WBEM EventID: 4911. WBEM ProviderName: FPL_IndicationProviderError11463
System backplane power has reported a 2.5v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 2.5v fault. Recommended Action: Check system backplane power board.
WBEM EventID: 4912. WBEM ProviderName: FPL_IndicationProviderError11465
One or more power rails is providing insufficient power to the backplane. Probable
Cause: There has been multiple faults on the same power rail. Recommended Action:
look for additional events describing action to take. WBEM EventID: 4913. WBEM
ProviderName: FPL_IndicationProviderError11467
Clock fault for clocks supplied from the Redundant Clock Source (RCS) board to the
system backplane. RCS board is no longer providing clocks to the backplane. The
data field contains the physical location of the RCS. Probable Cause: RCS assembly
has reported a fault. Recommended Action: Check RCS assembly. WBEM EventID:
4914. WBEM ProviderName: FPL_IndicationProviderError11468
86 WBEM Provider Event Tables