HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
IO Backplane +12V power fault. Probable Cause: One of the +12v VRM's is reporting
a fault. One failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board. Faulted VRM is given by
PS command. WBEM EventID: 6828. WBEM ProviderName: FPL_IndicationProviderError11569
IO Backplane 1.5V temperature fault. Probable Cause: One of the 1.5v VRM's is over
temp. Recommended Action: Check IO backplane power board faulted VRM is give
by PS command. WBEM EventID: 6829. WBEM ProviderName:
FPL_IndicationProviderError11575
IO Backplane 3.3V temperature fault. Probable Cause: One of the 3.3v VRM's is over
temp. Recommended Action: Check IO backplane power board faulted VRM is give
by PS command. WBEM EventID: 6830. WBEM ProviderName:
FPL_IndicationProviderError11576
IO Backplane -12.0V temperature fault. Probable Cause: One of the -12v VRM's is
over temp. Recommended Action: Check IO backplane power board faulted VRM
is give by PS command. WBEM EventID: 6831. WBEM ProviderName:
FPL_IndicationProviderError11578
IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is
over temp and has shutdown. One failure and the Redundancy state is 'not redundant',
after two power faults the redundancy state is 'insufficient'. Recommended Action:
Check IO backplane power board. Faulted VRM is given by PS command. WBEM
EventID: 6832. WBEM ProviderName: FPL_IndicationProviderError11579
The local cell was unable to clear the link_off bit on at least one CC-CC link. Data
field: return value of Phase3BackToBackPrep(). Probable Cause: An error occurred
while routing the fabric. Recommended Action: Collect IPMI event logs, and contact
your HP support representative to inspect the fabric and system firmware. WBEM
EventID: 4944. WBEM ProviderName: FPL_IndicationProviderWarning11580
ArfOLAPreRendez() was unable to reach the added cell. Data field: bitmap of
unreachable cells. Probable Cause: Firmware was unable to find a valid route to a
cell being added by OLA. Recommended Action: Collect IPMI event logs, and contact
your HP support representative to inspect the fabric and system firmware. WBEM
EventID: 4945. WBEM ProviderName: FPL_IndicationProviderWarning11581
An unexpected error occurred in SetupNCTable(). Data field: return value from
SetupNCTable(). Probable Cause: An error occurred while routing the fabric.
Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4946.
WBEM ProviderName: FPL_IndicationProviderWarning11582
Phase4BackToBackPrep() unexpectedly failed. Data field: return value of
Phase4BackToBackPrep(). Probable Cause: An error occurred while routing the fabric.
Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4947.
WBEM ProviderName: FPL_IndicationProviderWarning11583
Unable to synch graphs between all cells in the partition after an OLA. Data field:
(master cell number 56) | (bitmap of cells to synch). Probable Cause: An error occurred
while routing the fabric Recommended Action: Collect IPMI event logs, and contact
your HP support representative to inspect the fabric and system firmware. WBEM
EventID: 4948. WBEM ProviderName: FPL_IndicationProviderWarning11584
Data field: bitmap of unreachable cells. Probable Cause: An error occurred while
routing the fabric. Recommended Action: Collect IPMI event logs, and contact your
HP support representative to inspect the fabric and system firmware. WBEM EventID:
4949. WBEM ProviderName: FPL_IndicationProviderWarning11585
An unexpected error occurred while setting up the Non-Coherent or Coherent tables
after an OLA. Data field: return value from SetupNCTable() or SetupCohTable().
Probable Cause: An error occurred while routing the fabric. Recommended Action:
Collect IPMI event logs, and contact your HP support representative to inspect the
fabric and system firmware. WBEM EventID: 4950. WBEM ProviderName:
FPL_IndicationProviderWarning11586
Platform Events 89