HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
An ISA UART was created without a data structure. A PCI UART structure exists.
Probable Cause: The ISA UART code was called when a PCI UART structure and no
ISA UART structure were created. Recommended Action: Verify that the configuration
contains the correct UART type. WBEM EventID: 5138. WBEM ProviderName:
FPL_IndicationProviderError11705
A TCGETS or TCSETS IOCTL failed. The errno status will be in a subsequent event.
Probable Cause: The device is not configured or is not the proper type. Recommended
Action: Check the configuration WBEM EventID: 5139. WBEM ProviderName:
FPL_IndicationProviderError11706
A stat call on the PMAN failed. The next event contains the failure errno. Probable
Cause: The device does not exist or is not available Recommended Action: Check the
configuration and verify the device WBEM EventID: 5140. WBEM ProviderName:
FPL_IndicationProviderError11707
The virtual machine driver could not be opened. Probable Cause: The virtual machine
software is not properly installed or is not running Recommended Action: Restart
the virtual machine. If this fails verify that it is properly installed. WBEM EventID:
5141. WBEM ProviderName: FPL_IndicationProviderError11708
The virtual machine driver could not create a virtual machine. Probable Cause: The
PMAN kernel has insufficient memory available to create a guest Recommended
Action: Add memory or reduce memory use WBEM EventID: 5142. WBEM
ProviderName: FPL_IndicationProviderError11709
Could not create a file system node for communication between the vmm driver and
the virtual machine. The next event contains the error from the Unix system call.
Probable Cause: Insufficient resources or file system problem Recommended Action:
Verify that the root file system has no errors and is not full. WBEM EventID: 5143.
WBEM ProviderName: FPL_IndicationProviderError11710
The vm device was created but cannot be opened. Probable Cause: File system error
or PMAN has insufficient resources Recommended Action: Verify that the root file
system has no errors and that the PMAN has sufficient memory. WBEM EventID:
5144. WBEM ProviderName: FPL_IndicationProviderError11711
The virtual machine driver has not been loaded. Probable Cause: HPVM has not been
started Recommended Action: Start HPVM WBEM EventID: 5145. WBEM
ProviderName: FPL_IndicationProviderError11712
An attempt to create a thread on the PMAN has failed. The next event contains the
Unix error number. Probable Cause: Insufficient resources Recommended Action:
Reduce guest resources or add memory WBEM EventID: 5146. WBEM ProviderName:
FPL_IndicationProviderError11718
VM Driver was unable to communicate with virtual machine. Probable Cause: This
is an internal error. Recommended Action: If this continues to occur, reinstall the
software. If this does not fix the problem contact your HP support representative.
WBEM EventID: 5147. WBEM ProviderName: FPL_IndicationProviderError11719
The configuration file could not be read. Probable Cause: The configuration file is
missing or damaged. Recommended Action: Restore the configuration from a backup
or recreate the guest. WBEM EventID: 5148. WBEM ProviderName:
FPL_IndicationProviderError11720
Memory allocation for a firmware table has failed. The data contains the name of the
firmware table. Probable Cause: Insufficient memory available Recommended Action:
Increase available memory or swap file space WBEM EventID: 5149. WBEM
ProviderName: FPL_IndicationProviderError11721
Driver was unable to build map tables. Probable Cause: Insufficient resources or
PMAN kernel memory too fragmented Recommended Action: Add memory or reboot
WBEM EventID: 5150. WBEM ProviderName: FPL_IndicationProviderError11723
Platform Events 91