HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Reboot failed. The virtual machine will exit. Probable Cause: The virtual machine
was unable to restart. The next event contains the Unix error. Recommended Action:
Restart if possible WBEM EventID: 5151. WBEM ProviderName:
FPL_IndicationProviderError11724
SetupInitialCohTables() returned an error. Data field: (cell set 32) | (return value
from SetupInitialCohTables()). Probable Cause: An error occurred while routing the
fabric. Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4978.
WBEM ProviderName: FPL_IndicationProviderWarning11775
Stable store read or write to flash failed. Probable Cause: Soft error Flash part Failure
Recommended Action: Reboot, if problem persists, contact HP support WBEM
EventID: 5152. WBEM ProviderName: FPL_IndicationProviderWarning11780
Error reading or writing the stable store NVM area. Probable Cause: A read/write to
the NVM stable storage area failed Recommended Action: Reboot, if problem persists,
contact HP support WBEM EventID: 5153. WBEM ProviderName:
FPL_IndicationProviderWarning11783
FW has detected an illegal memory config using 4GB DIMMs. The system will be
halted. Probable Cause: An unsupported memory configuration with 4GB DIMMs
is installed in the system Recommended Action: Refer to the user documentation to
determine the supported memory configurations with 4GB DIMMs WBEM EventID:
5154. WBEM ProviderName: FPL_IndicationProviderError11784
SFW failed to allocate enough NVM to store all required data. Probable Cause: Not
enough space allocated to store all required data in NVM. Recommended Action:
Upgrade FW Contact HP support WBEM EventID: 6857. WBEM ProviderName:
FPL_IndicationProviderWarning11788
SFW failed to allocate enough SCR RAM to store all required data. Probable Cause:
SFW component does not allocate enough space in the SCR RAM for store it data.
Recommended Action: Update SFW. Contact your HP representative for support.
WBEM EventID: 6858. WBEM ProviderName: FPL_IndicationProviderWarning11789
SetupIntialCohTables() returned an error in ArfPhase3. Data field: cell set [63:32],
return value [31:0]. Probable Cause: An error occurred while routing the fabric.
Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 5157.
WBEM ProviderName: FPL_IndicationProviderWarning11797
Error writing the error masks for ALREC and ALTRAN. Data field: cell ID [63:56],
port num [55:44], XBC ID [43:32]. Probable Cause: An error occurred while routing
the fabric. Recommended Action: Collect IPMI event logs, and contact your HP
support representative to inspect the fabric and system firmware. WBEM EventID:
5161. WBEM ProviderName: FPL_IndicationProviderWarning11807
Firmware had an unexpected internal error from the vertex module.. Data field:
vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2
[15:0]. Probable Cause: An error occurred while routing the fabric, possible data
corruption or firmware error. Recommended Action: Collect IPMI event logs, and
contact your HP support representative to inspect the fabric and system firmware.
WBEM EventID: 5162. WBEM ProviderName: FPL_IndicationProviderWarning11840
The OS being booted is not supported in a partition containing a mix of processor
stepping revisions. Probable Cause: The OS being booted is not supported in a
partition containing a mix of processor stepping revisions. Recommended Action:
Failed processors should be replaced with like processors. Reconfigure the hardware
to avoid configurations with mixed steppings. WBEM EventID: 5163. WBEM
ProviderName: FPL_IndicationProviderError11850
92 WBEM Provider Event Tables