HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Firmware had an unexpected error while setting up links. Data field: vType1 [63:56]
| vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]. Probable
Cause: An error occurred while routing the fabric, possible data corruption or
firmware error. Recommended Action: Collect IPMI event logs, and contact your HP
support representative to inspect the fabric and system firmware. WBEM EventID:
5164. WBEM ProviderName: FPL_IndicationProviderWarning11851
Firmware was unable to write the Skyline global LINK_SEL_COHx CSR. Data field:
cell num [63:56] | link sel coh CSR (0 or 1) [0:0]. Probable Cause: An error occurred
while routing the fabric. Recommended Action: Collect IPMI event logs, and contact
your HP support representative to inspect the fabric and system firmware. WBEM
EventID: 5165. WBEM ProviderName: FPL_IndicationProviderWarning11863
The requested OS does not support booting with mixed CPU revisions. Probable
Cause: Mixed CPU revisions exist in a mixed-cpu stepping configuration.
Recommended Action: Replace cells to match cpu stepping revisions or deconfigure
the unmatched processors. WBEM EventID: 5166. WBEM ProviderName:
FPL_IndicationProviderWarning11870
System firmware experienced an error while updating the link sel value. Data field
indicates return status. Probable Cause: Error updating the global link select fabric
value Recommended Action: Contact your HP Support Representative to investigate
the fabric subsystem. WBEM EventID: 5167. WBEM ProviderName:
FPL_IndicationProviderWarning11885
Fabric was unable to generate a Skyline CSR address. Data field: cell number [63:56]
and return value from address function [31:0]. Probable Cause: An error occurred
while routing the fabric, possible data corruption or firmware error. Recommended
Action: Collect IPMI event logs, and contact your HP support representative to inspect
the fabric and system firmware. WBEM EventID: 5171. WBEM ProviderName:
FPL_IndicationProviderWarning11904
Firmware was unable to generate a Skyline CSR address. Data field: cell number
[63:56] | return value [31:0]. Probable Cause: An error occurred while routing the
fabric, possible data corruption or firmware error. Recommended Action: Collect
IPMI event logs, and contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 5172. WBEM ProviderName:
FPL_IndicationProviderWarning11905
Invalid or no OS boot rendezvous entry point for target CPU. Probable Cause: OS
or firmware bugs Recommended Action: Call HP support WBEM EventID: 5174.
WBEM ProviderName: FPL_IndicationProviderError11932
Checksum verification failed for OS_BOOT_RENDEZ entry point. Probable Cause:
Software data corruption Recommended Action: Call HP support WBEM EventID:
5175. WBEM ProviderName: FPL_IndicationProviderError11933
The System Firmware call to PAL_COPY_INFO failed. Probable Cause: Contact
Engineering, This is a bug. WBEM EventID: 5176. WBEM ProviderName:
FPL_IndicationProviderWarning11960
The System Firmware call to PAL_COPY_PAL failed. Probable Cause: Contact
Engineering, This is a bug. WBEM EventID: 5177. WBEM ProviderName:
FPL_IndicationProviderWarning11961
The System Firmware call to PAL_CACHE_FLUSH failed. Probable Cause: Contact
Engineering, This is a bug. WBEM EventID: 5178. WBEM ProviderName:
FPL_IndicationProviderWarning11962
Cell on line add/delete is not initialized. Probable Cause: Cell online add/delete was
attempted but the colad subsystem failed to initialize. Recommended Action: Contact
HP support. When this event is emitted, cell online add/delete is not usable. WBEM
EventID: 6897. WBEM ProviderName: FPL_IndicationProviderError11964
An FPARs component on which cell on-line add/delete depends is broken or missing.
Probable Cause: FPARs component on which cell on line add/delete depends is
broken or missing. Recommended Action: Do not use COLAD is FPARs mode WBEM
EventID: 6899. WBEM ProviderName: FPL_IndicationProviderError11966
Platform Events 93