HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Cell on-line add/delete in FPARs mode failed to get the FPARs semaphore. Probable
Cause: Cell on line add/delete in FPARs mode failed to get the FPARs semaphore.
Recommended Action: Do not use cell on line add/delete in FPARs mode. WBEM
EventID: 6900. WBEM ProviderName: FPL_IndicationProviderError11967
More than one processor from an FPAR called into cell on-line add/delete. Probable
Cause: More than one processor from an FPAR called into cell on line add/delete
Recommended Action: Do not use cell on line add/delete in FPARs mode WBEM
EventID: 6901. WBEM ProviderName: FPL_IndicationProviderError11968
All FPARs processors failed to rendezvous during a cell on line add/delete operation.
Probable Cause: All FPARs processors failed to rendezvous during a cell on line
add/delete operation. Recommended Action: Do not use cell on line add/delete in
FPARs mode WBEM EventID: 6902. WBEM ProviderName: FPL_IndicationProviderError11969
Encountered unexpected error during cell OLA activity. Probable Cause: New cell
cannot communicate with existing partition. Cell OLA failed. Recommended Action:
Existing partition can continue to run, new cell cannot be added to the partition.
WBEM EventID: 5179. WBEM ProviderName: FPL_IndicationProviderWarning11970
MCA occurred prior to completion of previous MCA. Probable Cause: An MCA
happened before a previous MCA event did not complete. Recommended Action:
For Fpars/Vpars, system FW will reset the hard partition. For npars, system FW will
still attempt to hand off to the OS_MCA handler, if OS_MCA handoff fails, the hard
partition will get reset. WBEM EventID: 5180. WBEM ProviderName:
FPL_IndicationProviderWarning11971
MCA during init event processing. Probable Cause: An MCA event happening before
a previous INIT event was not completely processed. Recommended Action: For
Fpars/Vpars, system FW will reset the hard partition. In Npars mode, MCA handler
will attempt to hand off to OS_MCA handler. If handoff fails, the hard partition will
be reset. WBEM EventID: 5181. WBEM ProviderName: FPL_IndicationProviderWarning11972
unable to find a bad edge in an untraversable route. Probable Cause: The bad edge
could not be found. Recommended Action: Check for intermittent link errors. Capture
IPMI event logs and look for additional error events. Contact your HP Support
Representative to investigate the fabric. WBEM EventID: 5182. WBEM ProviderName:
FPL_IndicationProviderWarning11974
Unknown entity drawing power from bus bars. WBEM EventID: 5183. WBEM
ProviderName: FPL_IndicationProviderWarning11989
Soft partition could not be booted, reverting to nPars. Probable Cause: A soft partition
could not be booted. Please refer to previous events for the complete details.
Recommended Action: The partition is rebooted to nPars to allow the soft partition
to be re-configured. WBEM EventID: 5184. WBEM ProviderName:
FPL_IndicationProviderError12001
Unable to route around broken link. Probable Cause: A traversable route between
the local cell and the specified destination crossbar could not be found Recommended
Action: Capture IPMI event logs. Contact your HP Support Representative to
investigate the fabric subsystem. WBEM EventID: 5187. WBEM ProviderName:
FPL_IndicationProviderWarning12008
Unable to set the APER 'fabric lockdown' bit. Probable Cause: Internal FW error.
Recommended Action: Reset partition WBEM EventID: 5188. WBEM ProviderName:
FPL_IndicationProviderWarning12013
An uncorrectable memory ECC error has occurred. The data field gives the physical
location of the DIMM that had the error. Probable Cause: An uncorrectable memory
ECC error has occurred. Recommended Action: Replace all DIMMs in the memory
rank specified in the physical location info. If problem persists, contact HP support
to troubleshoot the problem. WBEM EventID: 6860. WBEM ProviderName:
FPL_IndicationProviderError12017
94 WBEM Provider Event Tables