HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Duplicate DIMM serial numbers have been detected. Data field gives physical location
of DIMM. Check for other events specifying other DIMMs with same serial number.
Probable Cause: Multiple DIMMs have the same serial number. Recommended
Action: Replace DIMMs with duplicate serial numbers. Ensure new DIMMs have
unique serial numbers. WBEM EventID: 6564. WBEM ProviderName:
FPL_IndicationProviderWarning12135
The MP has lost lan communication with the UPS. WBEM EventID: 6833. WBEM
ProviderName: FPL_IndicationProviderWarning12143
The MP has re-gained lan communication with the UPS. WBEM EventID: 6834.
WBEM ProviderName: FPL_IndicationProviderWarning12144
An unrecoverable processor interrupt occurred while in IPF firmware. The data value
is the processor IFA. Probable Cause:. Probable bug in System Firmware, EFI driver,
EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset
applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM
Volume 2. Recommended Action: Provide console log containing register dump to
HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName:
FPL_IndicationProviderError12149
An unrecoverable processor interrupt occurred while in IPF firmware. The event
data is the processor ISR. Probable Cause:. Probable bug in System Firmware, EFI
driver, EFI app or OS loader (prior to OS launch). The event data field contains the
IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the
Intel ASDM Volume 2. Recommended Action: Provide console log containing register
dump to HP Customer Engineer. WBEM EventID: 6570. WBEM ProviderName:
FPL_IndicationProviderError12150
Double chip sparing has been invoked. Probable Cause: System firmware has detected
and corrected memory errors. Double chip sparing has been invoked to help mitigate
this condition. Recommended Action: On the next reboot, system firmware will test
the specified memory components, and may take them offline if the errors persist.
contact your HP support representative to check the specified memory components
at your next scheduled downtime WBEM EventID: 6572. WBEM ProviderName:
FPL_IndicationProviderWarning12153
External clock cable has been removed from the CPU cabinet. The data field contains
the physical location of the cabinet. Probable Cause: External clock cable has been
removed from the CPU cabinet. Recommended Action: Check external clock cable.
WBEM EventID: 6575. WBEM ProviderName: FPL_IndicationProviderError12155
System Fabric encountered a link error after opening up the fabric link. Probable
Cause: Fabric link errors were encountered Recommended Action: Collect IPMI event
logs. Contact your HP Support Representative to check the health of the system
fabric. WBEM EventID: 6576. WBEM ProviderName: FPL_IndicationProviderWarning12156
Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) |
(crossbar 32) | 1. Probable Cause: Fatal errors are present on the cell to crossbar links
Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6577. WBEM
ProviderName: FPL_IndicationProviderWarning12157
System firmware encountered fabric problems. Data Field: (crossbar port 44) |
(crossbar 32). Probable Cause: Errors occurred while collecting error data from a
fabric link Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6579. WBEM
ProviderName: FPL_IndicationProviderWarning12159
Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) |
(crossbar 32). Probable Cause: Fatal errors are present on a cell to crossbar link
Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6580. WBEM
ProviderName: FPL_IndicationProviderWarning12160
Platform Events 97