HP Integrity rx7620 Server - User Service Guide, Sixth Edition

CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions can result in damage to the server.
Figure 6-20 PCI Power Module Location
Preliminary Procedures
Before removing or replacing a PCI power module, follow these steps:
1. Identify the failed power supply. Table 6-4 describes the PCI-X Power Supply LED state.
2. Connect to ground with a wrist strap.
3. Visually inspect the replacement part for proper number and revision.
4. Shut down the partition and power off the PCI domain.
5. Remove the front bezel.
Table 6-4 PCI-X Power Supply LEDs
DescriptionStateDriven ByLED
All output voltages generated by the power supply are
within limits.
On GreenEach supplyPower
Power to entire system has been removed.Off
For LED status in combination with the green power LED
for PCI-X slot status, see Table 5-9.
YellowMP through PCI
LPM
1
Attention
114 Removing and Replacing Components